Skip to content

SMD code 8F-

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

79 parts are printed 8F-

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • TMPZ5231SOT-23AllNot recordedSOT-23All
    What it is
    Not recorded
    Maker
    All
    Package
    SOT-23
    Pins
    3
    Details
    Z-diode: 4,85..5,36V, Zzt<17Ω, 250mW
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • TMPZ5231RSOT-23AllNot recordedSOT-23All
    What it is
    Not recorded
    Maker
    All
    Package
    SOT-23
    Pins
    3
    Details
    Z-diode: 4,85..5,36V, Zzt<17Ω, 250mW
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • UN2216SOT-23PanNot recordedSOT-23Pan
    What it is
    Not recorded
    Maker
    Pan
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn-Digi: Sw, 50V, 100mA, 200mW, 150MHz, R1=4k7
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • UN5216SOT-523PanasonicNot recordedSOT-523Panasonic
    What it is
    Not recorded
    Maker
    Panasonic
    Package
    SOT-523
    Pins
    3
    Details
    Si-npn-Digi: Sw, 50V, 100mA, 150mW, 150MHz, R1=4k7
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • UNR2216SOT-23PanNot recordedSOT-23Pan
    What it is
    Not recorded
    Maker
    Pan
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn-Digi: Sw, 50V, 100mA, 200mW, 150MHz, R1=4k7
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • UNR5216SOT-523PanasonicNot recordedSOT-523Panasonic
    What it is
    Not recorded
    Maker
    Panasonic
    Package
    SOT-523
    Pins
    3
    Details
    Si-npn-Digi: Sw, 50V, 100mA, 150mW, 150MHz, R1=4k7
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 9 more parts have no package on record
    • UN9216JPanNot recordedNot recordedPan
      What it is
      Not recorded
      Maker
      Pan
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn-Digi: Sw, 50V, 100mA, 125mW, 150MHz, R1=4k7
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • UNR3216Digital transistor (PNP, resistors built in), PanasonicDigital transistor (PNP, resistors built in)Not recordedPanasonic
      What it is
      Digital transistor (PNP, resistors built in)
      Maker
      Panasonic
      Package
      Not recorded
      Pins
      Not recorded
      Details
      PNP transistor: Sw, 50V, 100mA, 100mW, 150MHz, R1=4.7k
      Source
      Published code list

      Is it dead? The meter test is below: Digital transistor.

    • UNR9216JPanNot recordedNot recordedPan
      What it is
      Not recorded
      Maker
      Pan
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn-Digi: Sw, 50V, 100mA, 125mW, 150MHz, R1=4k7
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • XC6127C25DNRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.5V±0.8%, -Reset PPO, -MR, Rdt=400ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6127N25JNRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.5V±0.8%, +Reset ODO, -MR, Rdt=400ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6129C25J9R-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.5V±0.8%, +Reset PPO, Detect Delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6129C25JNR-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.5V±0.8%, +Reset PPO, Detect Delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6129N25J9R-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.5V±0.8%, +Reset ODO, Detect Delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6129N25JNR-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.5V±0.8%, +Reset ODO, Detect Delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.