Skip to content

SMD code 8M in SOT-143

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 18 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • R3133Q41ECSOT-143Nisshinbo Micro DevicesNot recordedNisshinbo Micro Devices
    What it is
    Not recorded
    Maker
    Nisshinbo Micro Devices
    Package
    SOT-143
    Pins
    4
    Details
    CMOS-IC: Voltage Detector 4,1V, MR, Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 14 more parts have no package on record. Nothing rules them out, so they stay.
    • LDTC123JET1GDigital transistor (NPN, resistors built in), LRCDigital transistor (NPN, resistors built in)LRC
      What it is
      Digital transistor (NPN, resistors built in)
      Maker
      LRC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Digital transistor (bias resistors built in), NPN, IC 100 mA, VCEO 50 V
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Digital transistor.

    • S-LDTC123JET1GDigital transistor (NPN, resistors built in), LRCDigital transistor (NPN, resistors built in)LRC
      What it is
      Digital transistor (NPN, resistors built in)
      Maker
      LRC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Digital transistor (bias resistors built in), NPN, IC 100 mA, VCEO 50 V
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Digital transistor.

    • TCK108AGLoad switch, ToshibaLoad switchToshiba
      What it is
      Load switch
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      1.0 A Load Switch IC with Slew Rate Control Driver in Ultra Small Package
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Load switch.

    • AP7343D-16FS4-7BLDO regulator, Diodes IncorporatedLDO regulatorDiodes Incorporated
      What it is
      LDO regulator
      Maker
      Diodes Incorporated
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 1.6V±1%, 300mA, +CE, CL
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • IXD5127C33DNRVoltage supervisor, IXYSVoltage supervisorIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.3V±0.8%, -Reset PPO, -MR, 400ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5127N33JNRVoltage supervisor, IXYSVoltage supervisorIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.3V±0.8%, +Reset ODO, -MR, 400ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • UN921DJPanNot recordedPan
      What it is
      Not recorded
      Maker
      Pan
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn-Digi: Sw, 50V, 100mA, 125mW, 150MHz, R2=10k
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • UNR921DJPanNot recordedPan
      What it is
      Not recorded
      Maker
      Pan
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn-Digi: Sw, 50V, 100mA, 125mW, 150MHz, R2=10k
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • XC6127C33DNRVoltage supervisor, TorexVoltage supervisorTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.3V±0.8%, -Reset PPO, -MR, Rdt=400ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6127N33JNRVoltage supervisor, TorexVoltage supervisorTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.3V±0.8%, +Reset ODO, -MR, Rdt=400ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6129C33J9R-GVoltage supervisor, TorexVoltage supervisorTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.3V±0.8%, +Reset PPO, Detect Delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6129C33JNR-GVoltage supervisor, TorexVoltage supervisorTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.3V±0.8%, +Reset PPO, Detect Delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6129N33J9R-GVoltage supervisor, TorexVoltage supervisorTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.3V±0.8%, +Reset ODO, Detect Delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6129N33JNR-GVoltage supervisor, TorexVoltage supervisorTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.3V±0.8%, +Reset ODO, Detect Delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Load switch

Voltage, board powered, black probe on ground.

Working, it reads

Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

Dead, it reads

  • Output at the input voltage while switched off: the pass element has shorted.
  • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
On the board:
An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 8M

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.