SMD code 91
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
44 parts are printed 91
Not sure which one you have?
Answer up to 4 quick questions and these 44 parts are ranked, with a meter test that settles it. It works on a dead part too.
1.5SMC91SMCTVS diode, 2 pins, HottechTVS diodeSMC2 pinsHottech
- What it is
- TVS diode
- Maker
- Hottech
- Package
- SMC
- Pins
- 2
- Details
- TVS diode, VRWM 73.7 V, unidirectional
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
3.0SMC91SMCTVS diode, 2 pins, YFWTVS diodeSMC2 pinsYFW
- What it is
- TVS diode
- Maker
- YFW
- Package
- SMC
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
KDZ9.1EVSOD-523Zener diode, 2 pins, KECZener diodeSOD-5232 pinsKEC
- What it is
- Zener diode
- Maker
- KEC
- Package
- SOD-523
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
KDZ9.1VSOD-323Zener diode, 2 pins, KECZener diodeSOD-3232 pinsKEC
- What it is
- Zener diode
- Maker
- KEC
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
P6SMBF91SMBFTVS diode, 2 pins, YFWTVS diodeSMBF2 pinsYFW
- What it is
- TVS diode
- Maker
- YFW
- Package
- SMBF
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SD0571P6WDFN1610-2ESD protection diode, 2 pins, LeiditechESD protection diodeDFN1610-22 pinsLeiditech
- What it is
- ESD protection diode
- Maker
- Leiditech
- Package
- DFN1610-2
- Pins
- 2
- Details
- ESD protection diode, VRWM 5 V, Cj 960 pF
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMA2EZ91D5SMAZener diode, 2 pins, HXYZener diodeSMA2 pinsHXY
- What it is
- Zener diode
- Maker
- HXY
- Package
- SMA
- Pins
- 2
- Details
- Zener diode, 24 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
SML4763SMAZener diode, 2 pins, VishayZener diodeSMA2 pinsVishay
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SMA
- Pins
- 2
- Details
- 91 V Zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
TZD9.1WSSOD-323Zener diode, 2 pins, Taitron ComponentsZener diodeSOD-3232 pinsTaitron Components
- What it is
- Zener diode
- Maker
- Taitron Components
- Package
- SOD-323
- Pins
- 2
- Details
- SMD Zener Diodes (Two Terminals) - 200mW
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
TZD9.1WTSOD-523Zener diode, 2 pins, Taitron ComponentsZener diodeSOD-5232 pinsTaitron Components
- What it is
- Zener diode
- Maker
- Taitron Components
- Package
- SOD-523
- Pins
- 2
- Details
- SMD Zener Diodes (Two Terminals) - 150mW
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
EIA-96:910603Precision resistor (EIA-96 code), 2 pinsPrecision resistor (EIA-96 code)06032 pinsNot recorded
- What it is
- Precision resistor (EIA-96 code)
- Maker
- Not recorded
- Package
- 0603
- Pins
- 2
- Details
- EIA-96 precision chip resistor, code 91 stands for 866 in the E96 table; the printed mark adds a multiplier letter (91A = 866 Ohm, 91B = 8.66 kOhm)
- Source
- Added by hand from a published table
Is it dead? The meter test is below: Resistor.
4 more parts have no package on record
GSEY5U9600ESD protection diode, Good-ArkESD protection diodeNot recordedNot recordedGood-Ark
- What it is
- ESD protection diode
- Maker
- Good-Ark
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
USFZ9.1VZener diode, KECZener diodeNot recordedNot recordedKEC
- What it is
- Zener diode
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
02DZ9.1XZener diode, ToshibaZener diodeNot recordedNot recordedToshiba
- What it is
- Zener diode
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode: 8.50..9.00V, Iz=5mA, Zz=18, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
02DZ9.1YZener diode, ToshibaZener diodeNot recordedNot recordedToshiba
- What it is
- Zener diode
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode: 8.80..9.30V, Iz=5mA, Zz=18, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Resistor
Ohms range, across it, power off.
Working, it reads
Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.
Dead, it reads
- Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
- Well above its marked value: drifted high.
- On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
- On the board:
- A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
- Compare:
- The same position on another channel usually carries the same value, and so does the matching part on another board.
- Watch for:
- A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 91
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 4 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.