  • RBR5LAM40ASOD-128Schottky diode, 2 pins, ROHMSchottky diode2 pinsROHM
    What it is
    Schottky diode
    Maker
    ROHM
    Package
    SOD-128
    Pins
    2
    Details
    Schottky Barrier Diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • RBR5LAM40ATFSOD-128Schottky diode, 2 pins, ROHMSchottky diode2 pinsROHM
    What it is
    Schottky diode
    Maker
    ROHM
    Package
    SOD-128
    Pins
    2
    Details
    Schottky Barrier Diode (AEC-Q101 qualified)
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • 13 more parts have no package on record. Nothing rules them out, so they stay.
    • BAV222Switching diode, InfineonSwitching diodeNot recordedInfineon
      What it is
      Switching diode
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • BAW222Diode, InfineonDiodeNot recordedInfineon
      What it is
      Diode
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • BZX884B2V4Zener diode, Good-ArkZener diodeNot recordedGood-Ark
      What it is
      Zener diode
      Maker
      Good-Ark
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode, VZ 2.4 V, 0.25 W
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • FM4001-LRectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
      What it is
      Rectifier
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Rectifier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • FM4001-L-Q1Rectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
      What it is
      Rectifier
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Rectifier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • FM4001-MHRectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
      What it is
      Rectifier
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Rectifier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • FM4001-MH-Q1Rectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
      What it is
      Rectifier
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Rectifier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • FM4001-MSRectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
      What it is
      Rectifier
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Rectifier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • FM4001-MS-Q1Rectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
      What it is
      Rectifier
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Rectifier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • FM4001-MSTRectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
      What it is
      Rectifier
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Rectifier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • FM4001-MST-Q1Rectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
      What it is
      Rectifier
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Rectifier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • FM4001-SFRectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
      What it is
      Rectifier
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Rectifier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • FM4001-SF-Q1Rectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
      What it is
      Rectifier
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Rectifier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as A1

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 5 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.