SMD code A2 in SOD-523
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
13 parts in SOD-523 are printed A2
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
BB184SOD-523Varicap diode, 2 pins, NXPVaricap diodeSOD-5232 pinsNXP
- What it is
- Varicap diode
- Maker
- NXP
- Package
- SOD-523
- Pins
- 2
- Details
- UHF low voltage variable capacitance diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PIN diode or varicap.
EDZV5.1BSOD-523Zener diode, 2 pins, ROHMZener diodeSOD-5232 pinsROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- SOD-523
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
EDZVFH5.1BSOD-523Zener diode, 2 pins, ROHMZener diodeSOD-5232 pinsROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- SOD-523
- Pins
- 2
- Details
- Zener Diode (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LEDZ5.1BPT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-523
- Pins
- 2
- Details
- Zener diode, VZ Min 4.98 V, VZ Nom 5.1 V, VZ Max 5.2 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LEDZ5.1BT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-523
- Pins
- 2
- Details
- Zener diode, VZ Min 4.98 V, VZ Nom 5.1 V, VZ Max 5.2 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MMBD4148TSSOD-523Switching diode, 2 pins, PanjitSwitching diodeSOD-5232 pinsPanjit
- What it is
- Switching diode
- Maker
- Panjit
- Package
- SOD-523
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
MMBD4148TS-AUSOD-523Switching diode, 2 pins, PanjitSwitching diodeSOD-5232 pinsPanjit
- What it is
- Switching diode
- Maker
- Panjit
- Package
- SOD-523
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
S-LEDZ5.1BT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-523
- Pins
- 2
- Details
- Zener diode, VZ Min 4.98 V, VZ Nom 5.1 V, VZ Max 5.2 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
S-LEDZ5.1BT1G-SSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-523
- Pins
- 2
- Details
- Zener diode, VZ Min 4.98 V, VZ Nom 5.1 V, VZ Max 5.2 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
EDZ5.1BSOD-5232 pins, ROHMNot recordedSOD-5232 pinsROHM
- What it is
- Not recorded
- Maker
- ROHM
- Package
- SOD-523
- Pins
- 2
- Details
- Z-diode: 4.98..5.20V, Izt=5.0mA, Zzt=80Ω, 150mW
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
EDZS5.1BSOD-5232 pins, ROHMNot recordedSOD-5232 pinsROHM
- What it is
- Not recorded
- Maker
- ROHM
- Package
- SOD-523
- Pins
- 2
- Details
- Z-diode: 5,1V±10%, 5mA, 100mW
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
FDZ5.1EVSOD-523Zener diode, 2 pins, First SilionZener diodeSOD-5232 pinsFirst Silion
- What it is
- Zener diode
- Maker
- First Silion
- Package
- SOD-523
- Pins
- 2
- Details
- Zener diode: 4.980..5.20V, Izt=5mA, Zzt=80, 150mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
BAS16TSOT-523Switching diode, 3 pins, Formosa MicrosemiSwitching diodeSOT-5233 pinsFormosa Microsemi
- What it is
- Switching diode
- Maker
- Formosa Microsemi
- Package
- SOT-523
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
2 more parts have no package on record. Nothing rules them out, so they stay.
ADZ5.6BZener diode, ROHMZener diodeNot recordedNot recordedROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BGA2002RF amplifier (MMIC), 4 pins, NXPRF amplifier (MMIC)Not recorded4 pinsNXP
- What it is
- RF amplifier (MMIC)
- Maker
- NXP
- Package
- Not recorded
- Pins
- 4
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: RF amplifier.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
PIN diode or varicap
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
RF amplifier
Voltage, board powered, on the output pin that the bias resistor or choke feeds.
Working, it reads
The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.
Dead, it reads
- Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
- Output pin at the full supply voltage: open inside, no current flowing.
- On the board:
- Measured on the board with power on; the bias network is part of the reading.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The figures depend on the part and its bias resistor. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as A2
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.