SMD code A22 in SMA
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
3 parts in SMA are printed A22
Not sure which one you have?
Answer up to 4 quick questions and these 19 parts are ranked, with a meter test that settles it. It works on a dead part too.
FM202SMARectifier, 2 pins, Formosa MicrosemiRectifier2 pinsFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- SMA
- Pins
- 2
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM202-Q1SMARectifier, 2 pins, Formosa MicrosemiRectifier2 pinsFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- SMA
- Pins
- 2
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BV-SMAJ22ASMATVS diode, 2 pins, Bencent ElectronicsTVS diode2 pinsBencent Electronics
- What it is
- TVS diode
- Maker
- Bencent Electronics
- Package
- SMA
- Pins
- 2
- Details
- Transient voltage supressor: Vrwm=22V, Vbr=24.4..26.9V, 11.3A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
12 more parts have no package on record. Nothing rules them out, so they stay.
AP3P090NP-channel MOSFET, Advanced Power ElectronicsP-channel MOSFETNot recordedAdvanced Power Electronics
- What it is
- P-channel MOSFET
- Maker
- Advanced Power Electronics
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 30 V, 3.1 A P-channel MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
FM202-BSRectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM202-BS-Q1Rectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM202-LRectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM202-MSRectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM202-MSTRectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM202-SFRectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM202-SF-Q1Rectifier, Formosa MicrosemiRectifierNot recordedFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
2SK436JFET, SanyoJFETNot recordedSanyo
- What it is
- JFET
- Maker
- Sanyo
- Package
- Not recorded
- Pins
- Not recorded
- Details
- N-channel JFET
- Source
- Published code list
Is it dead? The meter test is below: JFET.
2SK436-22Sanyo ElectricNot recordedNot recordedSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- Not recorded
- Pins
- Not recorded
- Details
- FET n-type: RF-AM, LN, 15V, 20mA, 150mW, Idss=7.3..12mA
- Source
- Published code list
Is it dead? The meter test is below: MOSFET.
2SK1066-22Sanyo ElectricNot recordedNot recordedSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- Not recorded
- Pins
- Not recorded
- Details
- n-FET: GP, 15V, 20mA, 100mW, Idss=7,3..12mA, Up<1,5V
- Source
- Published code list
Is it dead? The meter test is below: MOSFET.
AD8597ACPZ-R28 pins, Analog DevicesNot recorded8 pinsAnalog Devices
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- Not recorded
- Pins
- 8
- Source
- Published code list
Is it dead? The meter test is below: This part.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
JFET
Ohms range for drain to source, diode range for the gate, part lifted.
Working, it reads
Drain to source conducts both ways at a few hundred ohms, depending on the part, and some meters beep on it. The gate reads one junction to drain and to source, about 0.6 to 0.7 V, and open the other way.
Dead, it reads
- The gate the same both ways to drain or source, near 0 V with a continuous beep: gate shorted.
- Drain to source open: the channel has failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- Drain to source resistance varies from part to part. An identical part elsewhere on the board shows what is normal.
- Watch for:
- A good channel can beep like a short between drain and source. That is normal; the gate junction says whether it has failed.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as A22
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with A22
For a marking with its end worn or burnt off. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.