  • MM1Z43BWSOD-123Zener diode, 2 pins, YFWZener diodeSOD-1232 pinsYFW
    What it is
    Zener diode
    Maker
    YFW
    Package
    SOD-123
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MMBD4448HTASOT-523Switching diode, 3 pins, Galaxy MicroelectronicsSwitching diodeSOT-5233 pinsGalaxy Microelectronics
    What it is
    Switching diode
    Maker
    Galaxy Microelectronics
    Package
    SOT-523
    Pins
    3
    Details
    0.25A, 85V, Surface Mount Small Signal Switching Diodes
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Silicon diode.

  • MMBD4448HTA-HFSOT-523Switching diode, 3 pins, ComchipSwitching diodeSOT-5233 pinsComchip
    What it is
    Switching diode
    Maker
    Comchip
    Package
    SOT-523
    Pins
    3
    Details
    85 V, 250 mA switching diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Silicon diode.

  • MMSZ5262BSOD-123FZener diode, 2 pins, DiotecZener diodeSOD-123F2 pinsDiotec
    What it is
    Zener diode
    Maker
    Diotec
    Package
    SOD-123F
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • NZ8F33VMX2WSOD-882Zener diode, 2 pins, onsemiZener diodeSOD-8822 pinsonsemi
    What it is
    Zener diode
    Maker
    onsemi
    Package
    SOD-882
    Pins
    2
    Details
    Zener Diode Voltage Regulators NZ8F Series
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • PMEG2020EHSOD-123FSchottky diode, 2 pins, NexperiaSchottky diodeSOD-123F2 pinsNexperia
    What it is
    Schottky diode
    Maker
    Nexperia
    Package
    SOD-123F
    Pins
    2
    Details
    20 V, 2 A very low VF Schottky barrier rectifier
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • PTVS7V5S1UR-MSSOD-123FTVS diode, 2 pins, MSKSEMITVS diodeSOD-123F2 pinsMSKSEMI
    What it is
    TVS diode
    Maker
    MSKSEMI
    Package
    SOD-123F
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • PZ2FD3V9HASOD-882Zener diode, 2 pins, PrisemiZener diodeSOD-8822 pinsPrisemi
    What it is
    Zener diode
    Maker
    Prisemi
    Package
    SOD-882
    Pins
    2
    Details
    Zener diode, 3.82 V, 1 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • 7 more parts have no package on record
    • NC7SZ38FHLogic gate, onsemiLogic gateNot recordedNot recordedonsemi
      What it is
      Logic gate
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      TinyLogic UHS 2-Input NAND Gate, Open Drain Output
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • NC7SZ38L6Logic gate, onsemiLogic gateNot recordedNot recordedonsemi
      What it is
      Logic gate
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      TinyLogic UHS 2-Input NAND Gate, Open Drain Output
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • NCP139AFCT06ADJLDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LDO Regulator - Very Low Dropout, CMOS, Bias Rail
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • NCP139AFCTC06ADJLDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LDO Regulator - Very Low Dropout, CMOS, Bias Rail
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • NCP164ASNADJLDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LDO Regulator, 300 mA, Low Dropout Voltage, Ultra Low Noise, High PSRR with Power Good
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • NZ8DH33VMXWESD protection diode, onsemiESD protection diodeNot recordedNot recordedonsemi
      What it is
      ESD protection diode
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener Protection Diode Series
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • RBR1L40ASchottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
      What it is
      Schottky diode
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Barrier Diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.