SMD marking

A71in SOT-23

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

Not sure which one you have?

Answer up to 4 quick questions and these 3 parts are ranked, with a meter test that settles it. It works on a dead part too.

The only part printed A71 in this package in our tables

PJA3471

What it is
MOSFET
Maker
Panjit
Package
SOT-23
Pins
3
Source
From the manufacturer's datasheet

Is it dead?

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted.
  • No body diode at all: failed open.
On the board:
On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread

These parts are printed with a character that is easy to misread as what you typed. The odd one out is marked on each.

TVS diode, all Vishay.

  • TA6L12Aprinted ATL

    Printed ATL on the part. Easy to misread as A71. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    600 W TVS diode, unidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TA6L12CAprinted ATL

    Printed ATL on the part. Easy to misread as A71. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    600 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Open this in the search to correct a character or try another package.