Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

4 parts in SOT-353 are printed AA-

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

15 parts have no package on record. Nothing rules them out, so they stay.

  • SDL03ESD protection diode, SeCoSESD protection diodeSeCoS
    What it is
    ESD protection diode
    Maker
    SeCoS
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SZEMI8032MUESD protection diode, onsemiESD protection diodeonsemi
    What it is
    ESD protection diode
    Maker
    onsemi
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Common Mode Filter with ESD Protection EMI803x Series
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 74AUP2G34GFNXPNot recordedNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Dual noniverting buffers
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74AUP2G34GMNXPNot recordedNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Dual noniverting buffers
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74AUP2G34GNNXPNot recordedNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Dual noniverting buffers
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74AUP2G34GSNXPNot recordedNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Dual noniverting buffers
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74AUP2G34GXNXPNot recordedNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Dual noniverting buffers
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74AUP3G34GFNXPNot recordedNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Triple buffer
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74AUP3G34GNNXPNot recordedNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Triple buffer
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74AUP3G34GSNXPNot recordedNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Triple buffer
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 74AUP3G34GXNXPNot recordedNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Triple buffer
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BAR80InfineonNot recordedInfineon
    What it is
    Not recorded
    Maker
    Infineon
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Si-diode: RF, Shunt, 35V, 100mA, Vf<1V(100mA), 0,6pF
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • BCP51MPNP transistor, InfineonPNP transistorInfineon
    What it is
    PNP transistor
    Maker
    Infineon
    Package
    Not recorded
    Pins
    5
    Details
    PNP transistor: AF-Dr/Out, 45V, 1A, 1.7W, B=40..250, 100MHz
    Source
    Published code list

    Is it dead? The meter test is below: PNP transistor.

  • BD7LS00G-CROHMNot recordedROHM
    What it is
    Not recorded
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: 2-input NAND gate
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BD48E23GVoltage supervisor, ROHMVoltage supervisorROHM
    What it is
    Voltage supervisor
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PNP transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.