SMD code AK in SMA
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
25 parts in SMA are printed AK
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
SZ1SMA30CAT3GSMATVS diode, HXYTVS diodeSMAHXY
- What it is
- TVS diode
- Maker
- HXY
- Package
- SMA
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
6.0SMAJ6.5CASMATVS diode, UN SemiconductorTVS diodeSMAUN Semiconductor
- What it is
- TVS diode
- Maker
- UN Semiconductor
- Package
- SMA
- Pins
- 2
- Details
- Transient voltage supressor: Vrwm=6.5V, Vbr=7.22..7.98V, Ipp=53.6A, 600W(1ms), Bidir.
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
EC76SMAJ6.5ASMATVS diode, E-CMOSTVS diodeSMAE-CMOS
- What it is
- TVS diode
- Maker
- E-CMOS
- Package
- SMA
- Pins
- 2
- Details
- Transient voltage supressor: Vbr=7.22..7.98V, Vrwm=6.5V, Ipp=35.7A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
P4SMA8.2ASMATVS diode, FagTVS diodeSMAFag
- What it is
- TVS diode
- Maker
- Fag
- Package
- SMA
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
P4SMA8V2ASMATVS diode, Fagor ElectronicaTVS diodeSMAFagor Electronica
- What it is
- TVS diode
- Maker
- Fagor Electronica
- Package
- SMA
- Pins
- 2
- Details
- Transient voltage supressor: Vbr=7.79..8.61V, Vrwm=8.2V, 33.1A, 400W (1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
P4SMAJ6.5ASMAMicro Commercial ComponentsNot recordedSMAMicro Commercial Components
- What it is
- Not recorded
- Maker
- Micro Commercial Components
- Package
- SMA
- Pins
- 2
- Details
- TVS: 6.5V, 35.7A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
TSMA8.2ASMATVS diode, VishayTVS diodeSMAVishay
- What it is
- TVS diode
- Maker
- Vishay
- Package
- SMA
- Pins
- 2
- Details
- Transient voltage supressor: Vbr=7.79..8.61V, Vrwm=7.02V, Ipp=35A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
TV04A6V5JSMAComchipNot recordedSMAComchip
- What it is
- Not recorded
- Maker
- Comchip
- Package
- SMA
- Pins
- 2
- Details
- TVS: 6.5V, 5%, 35.7A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
TV04A6V5J-GSMATVS diode, ComchipTVS diodeSMAComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMA
- Pins
- 2
- Details
- Transient voltage supressor: Vrwm=6.50V, Vbr=7.22..7.98V, Ipp=35.71A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
6 more parts have no package on record. Nothing rules them out, so they stay.
BCW60Transistor, InfineonTransistorNot recordedInfineon
- What it is
- Transistor
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Bipolar transistor.
BZX884B4V7LZener diode, VishayZener diodeNot recordedVishay
- What it is
- Zener diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 4.7 V Zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZX884B13Zener diode, Good-ArkZener diodeNot recordedGood-Ark
- What it is
- Zener diode
- Maker
- Good-Ark
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode, VZ 13 V, 0.25 W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZX884B13VZener diode, RectronZener diodeNot recordedRectron
- What it is
- Zener diode
- Maker
- Rectron
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
GSEZ5B151ESD protection diode, Good-ArkESD protection diodeNot recordedGood-Ark
- What it is
- ESD protection diode
- Maker
- Good-Ark
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
MSMP6.5ATVS diode, VishayTVS diodeNot recordedVishay
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 150 W TVS diode, unidirectional
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Bipolar transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.