SMD code AL in DFN
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
9 parts in DFN are printed AL
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
7WB3126MUDFNonsemiNot recordedonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- DFN
- Pins
- Not recorded
- Details
- CMOS logic IC: 2-Bit bus switch
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
7WBD383MUDFNonsemiNot recordedonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- DFN
- Pins
- Not recorded
- Details
- CMOS logic IC: Translating bus exchange switch
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
LD39020ADTPU40RDFNSGS-Thomson MicroelectronicsNot recordedSGS-Thomson Microelectronics
- What it is
- Not recorded
- Maker
- SGS-Thomson Microelectronics
- Package
- DFN
- Pins
- Not recorded
- Details
- equivalent [4.0V LDO]
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
MAX8840EYT27+TDFNLDO regulator, Maxim Integrated ProductsLDO regulatorMaxim Integrated Products
- What it is
- LDO regulator
- Maker
- Maxim Integrated Products
- Package
- DFN
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 2.7V±2%, 150mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
NCP5911MNTBGDFNonsemiNot recordedonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- DFN
- Pins
- Not recorded
- Details
- MOSFET driver
- Source
- Published code list
Is it dead? The meter test is below: MOSFET.
NL27WZ02MU1DFNonsemiNot recordedonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- DFN
- Pins
- Not recorded
- Details
- CMOS logic IC: Dual 2-input NOR gate
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
RP104K281BDFNLDO regulator, RicohLDO regulatorRicoh
- What it is
- LDO regulator
- Maker
- Ricoh
- Package
- DFN
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 2.8V±0.8%, 150mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
RT9011-FMPQVDFNRichtekNot recordedRichtek
- What it is
- Not recorded
- Maker
- Richtek
- Package
- DFN
- Pins
- Not recorded
- Details
- Voltage regulator
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
WL2815D28-4DFNVoltage supervisor, Will SemiconductorVoltage supervisorWill Semiconductor
- What it is
- Voltage supervisor
- Maker
- Will Semiconductor
- Package
- DFN
- Pins
- Not recorded
- Details
- Voltage detector IC: LDO, 2.8V±2%, 200mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
6 more parts have no package on record. Nothing rules them out, so they stay.
AOZ8300CI-03ESD protection diode, Alpha & Omega SemiconductorESD protection diodeAlpha & Omega Semiconductor
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection for high-speed interfaces
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
BZX884B5V1LZener diode, VishayZener diodeVishay
- What it is
- Zener diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 5.1 V Zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZX884B15Zener diode, Good-ArkZener diodeGood-Ark
- What it is
- Zener diode
- Maker
- Good-Ark
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode, VZ 15 V, 0.25 W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZX884B15VZener diode, RectronZener diodeRectron
- What it is
- Zener diode
- Maker
- Rectron
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
KTK7132EMOSFET, KECMOSFETKEC
- What it is
- MOSFET
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: MOSFET.
NCP139AFCT120LDO regulator, onsemiLDO regulatoronsemi
- What it is
- LDO regulator
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LDO Regulator - Very Low Dropout, CMOS, Bias Rail
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as AL
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.