Skip to content

SMD code AR

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • S-80728AL-ARSOT-893 pins, ABLICNot recordedSOT-893 pinsABLIC
    What it is
    Not recorded
    Maker
    ABLIC
    Package
    SOT-89
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • S-80728SL-ARSOT-23-55 pins, ABLICNot recordedSOT-23-55 pinsABLIC
    What it is
    Not recorded
    Maker
    ABLIC
    Package
    SOT-23-5
    Pins
    5
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • SiP825LEUSOT-23-5Voltage supervisor, 5 pins, VishayVoltage supervisorSOT-23-55 pinsVishay
    What it is
    Voltage supervisor
    Maker
    Vishay
    Package
    SOT-23-5
    Pins
    5
    Details
    CMOS-IC: Voltage Detector 4,63V, MR, ±Reset Push-pull output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • SiP6333R19D3SOT-23Voltage supervisor, 3 pins, VishayVoltage supervisorSOT-233 pinsVishay
    What it is
    Voltage supervisor
    Maker
    Vishay
    Package
    SOT-23
    Pins
    3
    Details
    CMOS-IC: Voltage Detector 1,9V, Reset Push-pull output 150ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • SMBG8.0CASMBGTVS diode, 2 pins, VishayTVS diodeSMBG2 pinsVishay
    What it is
    TVS diode
    Maker
    Vishay
    Package
    SMBG
    Pins
    2
    Details
    TVS: 8V, 44.1A, 600W(1ms), Bidirectional
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMBJ8.0ASMBTVS diode, 2 pins, VishayTVS diodeSMB2 pinsVishay
    What it is
    TVS diode
    Maker
    Vishay
    Package
    SMB
    Pins
    2
    Source
    An older or alternative marking, from a published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMBJ8.0CA-TSMBTVS diode, 2 pins, INPAQ TechnologyTVS diodeSMB2 pinsINPAQ Technology
    What it is
    TVS diode
    Maker
    INPAQ Technology
    Package
    SMB
    Pins
    2
    Details
    Transient voltage supressor: Vbr=8.89..9.83V, Vrwm=8.0V, Ipp=44.1A, 600W(1ms), Bidir.
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMWJ20ASOD-123WTVS diode, 2 pins, Fagor ElectronicaTVS diodeSOD-123W2 pinsFagor Electronica
    What it is
    TVS diode
    Maker
    Fagor Electronica
    Package
    SOD-123W
    Pins
    2
    Details
    Transient voltage supressor: Vbr=22.2..24.5V, Vvm=20V, Ipp=12.3A, 400W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SODJ8.0CA-SHSOD-123FTVS diode, 2 pins, LRCTVS diodeSOD-123F2 pinsLRC
    What it is
    TVS diode
    Maker
    LRC
    Package
    SOD-123F
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=8V, Vbr=8.89..9.83V, Ipp=20A(8.3ms), 200W(1ms), Bidir.
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SRA2210ESOT-5233 pins, AUK SemiconductorNot recordedSOT-5233 pinsAUK Semiconductor
    What it is
    Not recorded
    Maker
    AUK Semiconductor
    Package
    SOT-523
    Pins
    3
    Details
    Si-pnp-Digi: Sw, 50V, 100mA, 150mW, 200MHz, R1=4.7k
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • SRA2210USOT-3233 pins, AukNot recordedSOT-3233 pinsAuk
    What it is
    Not recorded
    Maker
    Auk
    Package
    SOT-323
    Pins
    3
    Details
    Si-pnp-Digi: Sw, 50V, 100mA, 200mW, 200MHz, R1=4.7k
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 4 more parts have no package on record
    • SMA6L8.0ATVS diode, LittelfuseTVS diodeNot recordedNot recordedLittelfuse
      What it is
      TVS diode
      Maker
      Littelfuse
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient voltage supressor: Vrwm=8.0V, Vbr=8.89..9.83V, 44.2A, 600W(1ms)
      Source
      Published code list

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • SMAS8.0ATVS diode, Formosa MicrosemiTVS diodeNot recordedNot recordedFormosa Microsemi
      What it is
      TVS diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient voltage supressor: Vrwm=8.0V, Vbr=8.89..9.83V, Ipp=29.4A, 400W(1ms)
      Source
      Published code list

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • SMBS8.0CATVS diode, Formosa MicrosemiTVS diodeNot recordedNot recordedFormosa Microsemi
      What it is
      TVS diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient voltage supressor: Vrwm=8.0V, Vbr=8.89..9.83V, Ipp=44.1A, 600W(1ms), Bidir.
      Source
      Published code list

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • SRA2210EFAukNot recordedNot recordedNot recordedAuk
      What it is
      Not recorded
      Maker
      Auk
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-pnp-Digi: Sw, 50V, 100mA, 150mW, 200MHz, R1=4.7k
      Source
      Published code list

      Is it dead? The meter test is below: This part.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.