Skip to content

SMD code AZ-

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

165 parts are printed AZ-

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 74AUP2G3404GWSOT-3636 pins, NXPSOT-3636 pinsNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    SOT-363
    Pins
    6
    Details
    CMOS logic IC: Inverting buffer with open-drain and inverter
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BCX70LRSOT-233 pins, InfineonSOT-233 pinsInfineon
    What it is
    Not recorded
    Maker
    Infineon
    Package
    SOT-23
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • BZT52-B6V2SSOD-3232 pins, Taiwan SemiconductorSOD-3232 pinsTaiwan Semiconductor
    What it is
    Zener diode
    Maker
    Taiwan Semiconductor
    Package
    SOD-323
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • 12 more parts have no package on record
    • 74AUP2G3404GMNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Inverting buffer with open-drain and inverter
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP2G3404GNNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Inverting buffer with open-drain and inverter
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP2G3404GSNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Inverting buffer with open-drain and inverter
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP3G3404DCNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual inverter and single buffer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP3G3404GDNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual inverter and single buffer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP3G3404GFNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual inverter and single buffer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP3G3404GMNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual inverter and single buffer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP3G3404GNNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual inverter and single buffer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP3G3404GSNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual inverter and single buffer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP3G3404GTNXPNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual inverter and single buffer
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD2243G6 pins, ROHMNot recorded6 pinsROHM
      What it is
      Not recorded
      Maker
      ROHM
      Package
      Not recorded
      Pins
      6
      Details
      1ch Adjustable Current Limit High Side Switch IC
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BGB707L7ESD7 pins, InfineonNot recorded7 pinsInfineon
      What it is
      Not recorded
      Maker
      Infineon
      Package
      Not recorded
      Pins
      7
      Source
      Published code list

      Is it dead? The meter test is below: This part.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.