SMD code B11 in SMB
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
1 part in SMB is printed B11
Not sure which one you have?
Answer up to 4 quick questions and these 3 parts are ranked, with a meter test that settles it. It works on a dead part too.
BV-SMBJ11ASMBTVS diode, Bencent ElectronicsTVS diodeBencent Electronics
- What it is
- TVS diode
- Maker
- Bencent Electronics
- Package
- SMB
- Pins
- 2
- Details
- Transient voltage supressor: Vrwm=11V, Vbr=12.2..14.0V, 33.0A, 600W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
2 more parts have no package on record. Nothing rules them out, so they stay.
SM2411PSANP-channel MOSFET, Sinopower SemiconductorP-channel MOSFETSinopower Semiconductor
- What it is
- P-channel MOSFET
- Maker
- Sinopower Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 30 V, 4.7 A P-channel MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
2SK1068-11Sanyo ElectricNot recordedSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- Not recorded
- Pins
- Not recorded
- Details
- n-FET: Impedance conv, 40V, 1mA, 0,1W, Idss=60..180µA, Up<4V
- Source
- Published code list
Is it dead? The meter test is below: MOSFET.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as B11
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with B11
For a marking with its end worn or burnt off. Each code has a page of its own.
- B11C3
- B1104
- B110C2
- B11A3
- B11V1
- B11D2
- B110V1
- B110A1
- B110D1
- B11B2
- B1133
- BILP2
- 8L10G1
- 8L12G1
- 8L15G1
- 8L18G1
- 81101
- 811A1
- 811B1
- 811M1
Codes not listed here are printed on 1 more part.
Did you find your part?
Open this in the search to correct a character or try another package.