SMD code B23
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
24 parts are printed B23
Not sure which one you have?
Answer up to 4 quick questions and these 24 parts are ranked, with a meter test that settles it. It works on a dead part too.
BSS123WSOT-323N-channel MOSFET, 3 pins, Taiwan SemiconductorN-channel MOSFETSOT-3233 pinsTaiwan Semiconductor
- What it is
- N-channel MOSFET
- Maker
- Taiwan Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- 100V, N Channel, Small Signal MOSFETs
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
KIC77B23MSOT-23Voltage supervisor, 3 pins, KECVoltage supervisorSOT-233 pinsKEC
- What it is
- Voltage supervisor
- Maker
- KEC
- Package
- SOT-23
- Pins
- 3
- Details
- CMOS system reset IC with delay time, 2.3 V detection
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
KIC77B23TSOT-23Voltage supervisor, 3 pins, KECVoltage supervisorSOT-233 pinsKEC
- What it is
- Voltage supervisor
- Maker
- KEC
- Package
- SOT-23
- Pins
- 3
- Details
- CMOS system reset IC with delay time, 2.3 V detection
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
SM2323PSASOT-23P-channel MOSFET, 3 pins, Sinopower SemiconductorP-channel MOSFETSOT-233 pinsSinopower Semiconductor
- What it is
- P-channel MOSFET
- Maker
- Sinopower Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- 30 V, 2.9 A P-channel MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
2SC3734-23SOT-233 pins, NEC ElectronicsNot recordedSOT-233 pinsNEC Electronics
- What it is
- Not recorded
- Maker
- NEC Electronics
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: Sw, 40V, 200mA, 200mW, B=100..200, >200MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SC3734B23SOT-233 pins, RenesasNot recordedSOT-233 pinsRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- SOT-23
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: This part.
AAT60223B-S5SOT-23-5Voltage supervisor, 5 pins, Advanced Analog TechnologyVoltage supervisorSOT-23-55 pinsAdvanced Analog Technology
- What it is
- Voltage supervisor
- Maker
- Advanced Analog Technology
- Package
- SOT-23-5
- Pins
- 5
- Details
- Voltage detector IC: 2.3V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AAT60223B-S15SOT-343Voltage supervisor, 4 pins, Advanced Analog TechnologyVoltage supervisorSOT-3434 pinsAdvanced Analog Technology
- What it is
- Voltage supervisor
- Maker
- Advanced Analog Technology
- Package
- SOT-343
- Pins
- 4
- Details
- Voltage detector IC: 2.3V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
B230LASMASchottky diode, 2 pins, VishaySchottky diodeSMA2 pinsVishay
- What it is
- Schottky diode
- Maker
- Vishay
- Package
- SMA
- Pins
- 2
- Details
- Si-diode: Schottky Rectifier, 30V, 2A, Vf<0,5V(2A)
- Source
- Published code list
Is it dead? The meter test is below: Schottky diode.
HE61CC1202MRSOT-23Voltage supervisor, 3 pins, Heermicr SemicconductorVoltage supervisorSOT-233 pinsHeermicr Semicconductor
- What it is
- Voltage supervisor
- Maker
- Heermicr Semicconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 1.2V±2%, +Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
HE7012HCMRSOT-23Voltage supervisor, 3 pins, Heermicr SemicconductorVoltage supervisorSOT-233 pinsHeermicr Semicconductor
- What it is
- Voltage supervisor
- Maker
- Heermicr Semicconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 1.2V±2%, +Reset PPO, Hst.
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
HE7012MCM5RSOT-23-5Voltage supervisor, 5 pins, Heermicr SemicconductorVoltage supervisorSOT-23-55 pinsHeermicr Semicconductor
- What it is
- Voltage supervisor
- Maker
- Heermicr Semicconductor
- Package
- SOT-23-5
- Pins
- 5
- Details
- Voltage detector IC: 1.2V±2%,+Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
HE7012MCNRSOT-23Voltage supervisor, 3 pins, Heermicr SemicconductorVoltage supervisorSOT-233 pinsHeermicr Semicconductor
- What it is
- Voltage supervisor
- Maker
- Heermicr Semicconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 1.2V±2%, +Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
2 more parts have no package on record
SM2423PSANP-channel MOSFET, Sinopower SemiconductorP-channel MOSFETNot recordedNot recordedSinopower Semiconductor
- What it is
- P-channel MOSFET
- Maker
- Sinopower Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 30 V, 2.8 A P-channel MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
TSMF23Schottky diode, Taitron ComponentsSchottky diodeNot recordedNot recordedTaitron Components
- What it is
- Schottky diode
- Maker
- Taitron Components
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Surface Mount Schottky Rectifiers
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as B23
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with B23
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 36 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.