SMD code BH in SMA
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
9 parts in SMA are printed BH
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
SMAJ13CA-TRSMATVS diode, 2 pins, STMicroelectronicsTVS diode2 pinsSTMicroelectronics
- What it is
- TVS diode
- Maker
- STMicroelectronics
- Package
- SMA
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMAJ14SMATVS diode, 2 pins, DOWOTVS diode2 pinsDOWO
- What it is
- TVS diode
- Maker
- DOWO
- Package
- SMA
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
EC76SMAJ14SMATVS diode, 2 pins, E-CMOSTVS diode2 pinsE-CMOS
- What it is
- TVS diode
- Maker
- E-CMOS
- Package
- SMA
- Pins
- 2
- Details
- Transient voltage supressor: Vbr=15.6..19.1V, Vrwm=14V, Ipp=15.5A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
P4SMA22SMATVS diode, 2 pins, FagTVS diode2 pinsFag
- What it is
- TVS diode
- Maker
- Fag
- Package
- SMA
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
P4SMAJ14SMATVS diode, 2 pins, Shanghai Lunsure Electronic TechnologyTVS diode2 pinsShanghai Lunsure Electronic Technology
- What it is
- TVS diode
- Maker
- Shanghai Lunsure Electronic Technology
- Package
- SMA
- Pins
- 2
- Details
- TVS: 14V, 15.5A, 400W (1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
SMAJ13CASMATVS diode, 2 pins, SGS-Thomson MicroelectronicsTVS diode2 pinsSGS-Thomson Microelectronics
- What it is
- TVS diode
- Maker
- SGS-Thomson Microelectronics
- Package
- SMA
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
TSMA22SMATVS diode, 2 pins, VishayTVS diode2 pinsVishay
- What it is
- TVS diode
- Maker
- Vishay
- Package
- SMA
- Pins
- 2
- Details
- Transient voltage supressor: Vbr=19.8..24.2V, Vrwm=17.8V, Ipp=13A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
TV04A140KSMA2 pins, ComchipNot recorded2 pinsComchip
- What it is
- Not recorded
- Maker
- Comchip
- Package
- SMA
- Pins
- 2
- Details
- TVS: 14V, 10%, 15.5A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
TV04A140K-GSMATVS diode, 2 pins, ComchipTVS diode2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMA
- Pins
- 2
- Details
- Transient voltage supressor: Vrwm=14.0V, Vbr=15.60..19.10V, Ipp=15.50A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
6 more parts have no package on record. Nothing rules them out, so they stay.
ACDBUC0320-HFSchottky diode, ComchipSchottky diodeNot recordedComchip
- What it is
- Schottky diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 20 V, 0.35 A Schottky barrier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
AOZ8915CIESD protection diode, Alpha & Omega SemiconductorESD protection diodeNot recordedAlpha & Omega Semiconductor
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection for high-speed interfaces
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
AOZ8915CILESD protection diode, Alpha & Omega SemiconductorESD protection diodeNot recordedAlpha & Omega Semiconductor
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection for high-speed interfaces
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
BZX884B33LZener diode, VishayZener diodeNot recordedVishay
- What it is
- Zener diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 33 V Zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
CDBU0320-HFSchottky diode, ComchipSchottky diodeNot recordedComchip
- What it is
- Schottky diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 20 V, 0.35 A Schottky barrier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
CDBUR0320-HFSchottky diode, ComchipSchottky diodeNot recordedComchip
- What it is
- Schottky diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 20 V, 0.35 A Schottky barrier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as BH
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with BH
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 46 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.