SMD code BT-
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
140 parts are printed BT-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
PAM28DOAC18ASMATVS diode, 2 pins, ProTek DevicesTVS diodeSMA2 pinsProTek Devices
- What it is
- TVS diode
- Maker
- ProTek Devices
- Package
- SMA
- Pins
- 2
- Details
- 400 Watt TVS Component
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PAM29DOAA18CASMBTVS diode, 2 pins, ProTek DevicesTVS diodeSMB2 pinsProTek Devices
- What it is
- TVS diode
- Maker
- ProTek Devices
- Package
- SMB
- Pins
- 2
- Details
- 600 Watt TVS Component
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PSMF18ALSOD-123FTVS diode, 2 pins, ProTek DevicesTVS diodeSOD-123F2 pinsProTek Devices
- What it is
- TVS diode
- Maker
- ProTek Devices
- Package
- SOD-123F
- Pins
- 2
- Details
- 400W TVS Component
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PTVSHC1RF18VUSOD-123FTVS diode, 2 pins, PrisemiTVS diodeSOD-123F2 pinsPrisemi
- What it is
- TVS diode
- Maker
- Prisemi
- Package
- SOD-123F
- Pins
- 2
- Details
- TVS diode, 18 V working
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PTVSHC1RF18VUHSOD-123FTVS diode, 2 pins, PrisemiTVS diodeSOD-123F2 pinsPrisemi
- What it is
- TVS diode
- Maker
- Prisemi
- Package
- SOD-123F
- Pins
- 2
- Details
- TVS diode, 18 V working
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
S-LBZT52MB4V3T1GSOD-123Zener diode, 2 pins, LRCZener diodeSOD-1232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-123
- Pins
- 2
- Details
- Zener diode, VZ Min 4.21 V, VZ Max 4.39 V, Vz@IZT mA 5
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
S-LUDZS4.3MBT1GSOD-323Zener diode, 2 pins, LRCZener diodeSOD-3232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-323
- Pins
- 2
- Details
- Zener diode, VZ Min 4.21 V, VZ Max 4.39 V, Vz@IZT mA 5
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
SMA6F18CA-HFSMAFTVS diode, 2 pins, ComchipTVS diodeSMAF2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMAF
- Pins
- 2
- Details
- 18 V 600 W bidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMA6J18CASMAFTVS diode, 2 pins, Formosa MicrosemiTVS diodeSMAF2 pinsFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- SMAF
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMAJ18ASMATVS diode, 2 pins, SOCAYTVS diodeSMA2 pinsSOCAY
- What it is
- TVS diode
- Maker
- SOCAY
- Package
- SMA
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
5 more parts have no package on record
PBZL150Zener diode, ROHMZener diodeNot recordedNot recordedROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
SFS18ATVS diode, SeCoSTVS diodeNot recordedNot recordedSeCoS
- What it is
- TVS diode
- Maker
- SeCoS
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMAFJ18ATVS diode, Blue RocketTVS diodeNot recordedNot recordedBlue Rocket
- What it is
- TVS diode
- Maker
- Blue Rocket
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMAFJ18A-MSTVS diode, MSKSEMITVS diodeNot recordedNot recordedMSKSEMI
- What it is
- TVS diode
- Maker
- MSKSEMI
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMAHFL18ATVS diode, Formosa MicrosemiTVS diodeNot recordedNot recordedFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.