SMD code C in SOT-723
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
1 part in SOT-723 is printed C
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
15 parts have no package on record. Nothing rules them out, so they stay.
ESDBU3V3A1ESD protection diode, JSCJESD protection diodeJSCJ
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 3.3 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESDBU3V3AE1ESD protection diode, JSCJESD protection diodeJSCJ
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 3.3 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
GSEN5B003ESD protection diode, Good-ArkESD protection diodeGood-Ark
- What it is
- ESD protection diode
- Maker
- Good-Ark
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
GSEZ5B018ESD protection diode, Good-ArkESD protection diodeGood-Ark
- What it is
- ESD protection diode
- Maker
- Good-Ark
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
GSEZ5B159ESD protection diode, Good-ArkESD protection diodeGood-Ark
- What it is
- ESD protection diode
- Maker
- Good-Ark
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
JEB05ULCDS-ATVS diode, JieJieTVS diodeJieJie
- What it is
- TVS diode
- Maker
- JieJie
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
KLFM07540-USchottky diode, Formosa MicrosemiSchottky diodeFormosa Microsemi
- What it is
- Schottky diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LESD11LLF5.0CT5GESD protection diode, LRCESD protection diodeLRC
- What it is
- ESD protection diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V, IR @VRWM 0.5 μA, VBR Min 6 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
LMBR05S40ST5GSchottky diode, LRCSchottky diodeLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky diode, VR 40 V, IF 0.5 A, VF Max 0.525 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
NCP110AFCT060LDO regulator, onsemiLDO regulatoronsemi
- What it is
- LDO regulator
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Linear Regulator - Low V , Low Noise, High PSRR
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
NCP508MT25LDO regulator, onsemiLDO regulatoronsemi
- What it is
- LDO regulator
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Very Low Noise, Fast Turn On, 50 mA Low Dropout Voltage Regulator
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
PG48FBUSCESD protection diode, KECESD protection diodeKEC
- What it is
- ESD protection diode
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PHS508ESD protection diode, ProTek DevicesESD protection diodeProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- Not recorded
- Pins
- Not recorded
- Details
- High Powered Surge Protection TVS Array
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
RB521SSchottky diode, Formosa MicrosemiSchottky diodeFormosa Microsemi
- What it is
- Schottky diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
RB521S-Q1Schottky diode, Formosa MicrosemiSchottky diodeFormosa Microsemi
- What it is
- Schottky diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.