Skip to content

SMD code C3 in SOT-323

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 45 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 1PS302SOT-323Switching diode, NexperiaSwitching diodeNexperia
    What it is
    Switching diode
    Maker
    Nexperia
    Package
    SOT-323
    Pins
    3
    Details
    Dual high-speed switching diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Silicon diode.

  • MMBZ5223BWSOT-323Zener diode, DC ComponentsZener diodeDC Components
    What it is
    Zener diode
    Maker
    DC Components
    Package
    SOT-323
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • 1SS302SOT-323Switching diode, ToshibaSwitching diodeToshiba
    What it is
    Switching diode
    Maker
    Toshiba
    Package
    SOT-323
    Pins
    3
    Details
    dual series fast sw 80V 100mA 1.6nS
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • AP8821C-23GTSOT-323Voltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
    What it is
    Voltage supervisor
    Maker
    Anwell Semiconductor
    Package
    SOT-323
    Pins
    3
    Details
    Voltage detector IC: 2.3V±2%, -Reset PPO, H-free
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • AP8821C-23PTSOT-323Voltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
    What it is
    Voltage supervisor
    Maker
    Anwell Semiconductor
    Package
    SOT-323
    Pins
    3
    Details
    Voltage detector IC: 2.3V±2%, -Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • APE6812U-CSOT-323Voltage supervisor, Advanced Power ElectronicsVoltage supervisorAdvanced Power Electronics
    What it is
    Voltage supervisor
    Maker
    Advanced Power Electronics
    Package
    SOT-323
    Pins
    3
    Details
    Voltage detector IC: 4.00V±2%, +Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • EC95808C23C1NSOT-323Voltage supervisor, E-CMOSVoltage supervisorE-CMOS
    What it is
    Voltage supervisor
    Maker
    E-CMOS
    Package
    SOT-323
    Pins
    3
    Details
    Voltage detector IC: 2.3V±2%, -Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • HSMS-282ESOT-323Agilent TechnologiesNot recordedAgilent Technologies
    What it is
    Not recorded
    Maker
    Agilent Technologies
    Package
    SOT-323
    Pins
    3
    Details
    Si-diode: Dual, Schtk, RF, 15V, 1A, Vf<0,34V(1mA), <1pF, 12Ω(5mA)
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • ILC5062IC23XSOT-323IMPNot recordedIMP
    What it is
    Not recorded
    Maker
    IMP
    Package
    SOT-323
    Pins
    3
    Details
    CMOS-IC: Voltage Detector 2.3V±2%, -Reset Push-pull output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 6 more parts have no package on record. Nothing rules them out, so they stay.
    • BAT54LW-CSwitching diode, SeCoSSwitching diodeSeCoS
      What it is
      Switching diode
      Maker
      SeCoS
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • BAV99-226Switching diode, Taitron ComponentsSwitching diodeTaitron Components
      What it is
      Switching diode
      Maker
      Taitron Components
      Package
      Not recorded
      Pins
      Not recorded
      Details
      SMD Switching Diodes (Three Terminals)
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • BZX884B20Zener diode, Good-ArkZener diodeGood-Ark
      What it is
      Zener diode
      Maker
      Good-Ark
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode, VZ 20 V, 0.25 W
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • BZX884B20VZener diode, RectronZener diodeRectron
      What it is
      Zener diode
      Maker
      Rectron
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • KDS122Switching diode, KECSwitching diodeKEC
      What it is
      Switching diode
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • MMSZ5223BHEZener diode, Galaxy MicroelectronicsZener diodeGalaxy Microelectronics
      What it is
      Zener diode
      Maker
      Galaxy Microelectronics
      Package
      Not recorded
      Pins
      Not recorded
      Details
      2.7V, 500mW, Surface Mount Zener Diodes
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as C3

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.