  • GSBAS40MC9SOD-923Schottky diode, Good-ArkSchottky diodeGood-Ark
    What it is
    Schottky diode
    Maker
    Good-Ark
    Package
    SOD-923
    Pins
    2
    Details
    Schottky diode, 40 V, 200 mA
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • 14 more parts have no package on record. Nothing rules them out, so they stay.
    • BZT52C39KZener diode, Taiwan SemiconductorZener diodeTaiwan Semiconductor
      What it is
      Zener diode
      Maker
      Taiwan Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • BZX884B36Zener diode, Good-ArkZener diodeGood-Ark
      What it is
      Zener diode
      Maker
      Good-Ark
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode, VZ 36 V, 0.25 W
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • BZX884B36VZener diode, RectronZener diodeRectron
      What it is
      Zener diode
      Maker
      Rectron
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • MM5Z39V-Q1Zener diode, Formosa MicrosemiZener diodeFormosa Microsemi
      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • ULC0321CDNHESD protection diode, LeiditechESD protection diodeLeiditech
      What it is
      ESD protection diode
      Maker
      Leiditech
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 3.3 V, Cj 0.26 pF
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • 1SS307EToshibaNot recordedToshiba
      What it is
      Not recorded
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Diode: Sw, 80V, 100mA, Vf=0.9V(100mA), 2pF
      Source
      Published code list

      Is it dead? The meter test is below: Silicon diode.

    • 2SC5231-9Sanyo ElectricNot recordedSanyo Electric
      What it is
      Not recorded
      Maker
      Sanyo Electric
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn: VHF/UHF, LN, 20V, 70mA, 100mW, B=135..270, 7GHz
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • AP130-50TWAnachipNot recordedAnachip
      What it is
      Not recorded
      Maker
      Anachip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      VR-IC: LDO, 5V±2%, 300mA
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • AP8821C-29GIVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.9V±2%, -Reset PPO, H-free
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8821C-29GSVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.9V±2%, -Reset PPO, H-free
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8821C-29PIVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.9V±2%, -Reset PPO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8821C-29PSVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.9V±2%, -Reset PPO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD45E471G-MVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.7V±1%, -MR, -Reset ODO, Rdt=100ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • EC95808C29C7IVoltage supervisor, E-CMOSVoltage supervisorE-CMOS
      What it is
      Voltage supervisor
      Maker
      E-CMOS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.9V±2%, -Reset PPO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as C9

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with C9

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 77 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.