SMD code CES
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
9 parts are printed CES
Not sure which one you have?
Answer up to 4 quick questions and these 9 parts are ranked, with a meter test that settles it. It works on a dead part too.
SMBJ26CASSMBTVS diode, 2 pins, JieJieTVS diodeSMB2 pinsJieJie
- What it is
- TVS diode
- Maker
- JieJie
- Package
- SMB
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
2SC3649SSOT-893 pins, onsemiNot recordedSOT-893 pinsonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- SOT-89
- Pins
- 3
- Details
- NPN HV comp 2SA1419S
- Source
- Published code list
Is it dead? The meter test is below: This part.
AD7476SRTZ-R2SOT-23-66 pins, Analog DevicesNot recordedSOT-23-66 pinsAnalog Devices
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- SOT-23-6
- Pins
- 6
- Source
- Published code list
Is it dead? The meter test is below: This part.
BSS79BSOT-233 pins, InfineonNot recordedSOT-233 pinsInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: Sw, 75V, 800mA, 330mW, B=40..120, >250MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
XC6116E024MRSOT-23-5Voltage supervisor, 5 pins, TorexVoltage supervisorSOT-23-55 pinsTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- SOT-23-5
- Pins
- 5
- Details
- CMOS-IC: VDet 2.4V 0.1%, -MR, ±Reset PPO, Rt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC9265C33BMR-GSOT-23-5DC-DC converter, 5 pins, TorexDC-DC converterSOT-23-55 pinsTorex
- What it is
- DC-DC converter
- Maker
- Torex
- Package
- SOT-23-5
- Pins
- 5
- Details
- DC/DC voltage converter IC: PFM st-dwn, 3.35V±2%, 200mA, +CE, CL
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
3 more parts have no package on record
2SC3649-SSanyo ElectricNot recordedNot recordedNot recordedSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Si-npn: HV, Sw, 180V, 1,5A, 500mW, B=140..280, 120MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
S-8244AASPH-CESTF8 pins, ABLICNot recordedNot recorded8 pinsABLIC
- What it is
- Not recorded
- Maker
- ABLIC
- Package
- Not recorded
- Pins
- 8
- Source
- Published code list
Is it dead? The meter test is below: This part.
XC9265C33B4R-GDC-DC converter, TorexDC-DC converterNot recordedNot recordedTorex
- What it is
- DC-DC converter
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- DC/DC voltage converter IC: PFM st-dwn, 3.35V±2%, 200mA, +CE, CL
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as CES
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with CES
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 78 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.