SMD code CNE
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
12 parts are printed CNE
Not sure which one you have?
Answer up to 4 quick questions and these 12 parts are ranked, with a meter test that settles it. It works on a dead part too.
1SMB54ASMBTVS diode, 2 pins, Central SemiconductorTVS diodeSMB2 pinsCentral Semiconductor
- What it is
- TVS diode
- Maker
- Central Semiconductor
- Package
- SMB
- Pins
- 2
- Details
- TVS: 54V, 6.9A, 500W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
2SA4548ESOT-893 pins, onsemiNot recordedSOT-893 pinsonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- SOT-89
- Pins
- 3
- Details
- NPN HV Sw Comp 2SA1740E
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SC4548-ESOT-89NPN transistor, 3 pins, Sanyo ElectricNPN transistorSOT-893 pinsSanyo Electric
- What it is
- NPN transistor
- Maker
- Sanyo Electric
- Package
- SOT-89
- Pins
- 3
- Details
- 400V, 0.2A, General Purpose NPN Bipolar Transistor
- Source
- Published code list
Is it dead? The meter test is below: NPN transistor.
AM61CN1502MSOT-23Voltage supervisor, 3 pins, Xiang Shuo ElectronicsVoltage supervisorSOT-233 pinsXiang Shuo Electronics
- What it is
- Voltage supervisor
- Maker
- Xiang Shuo Electronics
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 1.5V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AM61CN1502PSOT-89Voltage supervisor, 3 pins, Xiang Shuo ElectronicsVoltage supervisorSOT-893 pinsXiang Shuo Electronics
- What it is
- Voltage supervisor
- Maker
- Xiang Shuo Electronics
- Package
- SOT-89
- Pins
- 3
- Details
- Voltage detector IC: 1.5V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
HM61N1502MRSOT-23Voltage supervisor, 3 pins, Heermicr SemicconductorVoltage supervisorSOT-233 pinsHeermicr Semicconductor
- What it is
- Voltage supervisor
- Maker
- Heermicr Semicconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 1.5V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
HM61N1502NRSOT-23-5Voltage supervisor, 5 pins, Huamei SemiconductorVoltage supervisorSOT-23-55 pinsHuamei Semiconductor
- What it is
- Voltage supervisor
- Maker
- Huamei Semiconductor
- Package
- SOT-23-5
- Pins
- 5
- Details
- Voltage detector IC: 1.5V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
HM61N1502PRSOT-89Voltage supervisor, 3 pins, Heermicr SemicconductorVoltage supervisorSOT-893 pinsHeermicr Semicconductor
- What it is
- Voltage supervisor
- Maker
- Heermicr Semicconductor
- Package
- SOT-89
- Pins
- 3
- Details
- Voltage detector IC: 1.5V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
LN61CN1502MSOT-23Voltage supervisor, 3 pins, Shanghai Natlinear ElectronicsVoltage supervisorSOT-233 pinsShanghai Natlinear Electronics
- What it is
- Voltage supervisor
- Maker
- Shanghai Natlinear Electronics
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 1.5V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
LN61CN1502PSOT-89Voltage supervisor, 3 pins, Shanghai Natlinear ElectronicsVoltage supervisorSOT-893 pinsShanghai Natlinear Electronics
- What it is
- Voltage supervisor
- Maker
- Shanghai Natlinear Electronics
- Package
- SOT-89
- Pins
- 3
- Details
- Voltage detector IC: 1.5V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
2 more parts have no package on record
AM61CN1502NVoltage supervisor, Xiang Shuo ElectronicsVoltage supervisorNot recordedNot recordedXiang Shuo Electronics
- What it is
- Voltage supervisor
- Maker
- Xiang Shuo Electronics
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 1.5V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
LN61CN1502NVoltage supervisor, Shanghai Natlinear ElectronicsVoltage supervisorNot recordedNot recordedShanghai Natlinear Electronics
- What it is
- Voltage supervisor
- Maker
- Shanghai Natlinear Electronics
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 1.5V±2%, +Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
NPN transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as CNE
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with CNE
For a marking with its end worn or burnt off. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.