SMD code D in SOT-416
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
1 part in SOT-416 is printed D
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
15 parts have no package on record. Nothing rules them out, so they stay.
SZNZ9F4V3SZener diode, onsemiZener diodeNot recordedonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener Voltage Regulators SERIES
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
TCR3DG45LDO regulator, ToshibaLDO regulatorNot recordedToshiba
- What it is
- LDO regulator
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- TCR3DG series
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
TCR3UG095ALDO regulator, ToshibaLDO regulatorNot recordedToshiba
- What it is
- LDO regulator
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- TCR3UG series
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
TCR4DG115LDO regulator, ToshibaLDO regulatorNot recordedToshiba
- What it is
- LDO regulator
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- TCR4DG series
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
TCR5RG105ALDO regulator, ToshibaLDO regulatorNot recordedToshiba
- What it is
- LDO regulator
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- TCR5RG series
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
TESDH5V0B05P1Q1ESD protection diode, Taiwan SemiconductorESD protection diodeNot recordedTaiwan Semiconductor
- What it is
- ESD protection diode
- Maker
- Taiwan Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
TESDL24VB17P1Q1ESD protection diode, Taiwan SemiconductorESD protection diodeNot recordedTaiwan Semiconductor
- What it is
- ESD protection diode
- Maker
- Taiwan Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
TPS7A0228PYCHLDO regulator, 4 pins, Texas InstrumentsLDO regulator4 pinsTexas Instruments
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 4
- Details
- Nanopower IQ, 25-nA, 200-mA, Low-Dropout Voltage Regulator With Fast Transient Response
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
TPS7A1011PYKALDO regulator, 5 pins, Texas InstrumentsLDO regulator5 pinsTexas Instruments
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 5
- Details
- 300-mA, Low VIN, Low VOUT, Ultra-Low Dropout Regulator
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
TPS7A2018PYCKLDO regulator, 4 pins, Texas InstrumentsLDO regulator4 pinsTexas Instruments
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 4
- Details
- 300mA, Ultra-Low-Noise, Low-IQ, High PSRR LDO
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
VBUS54DD-HS4ESD protection diode, VishayESD protection diodeNot recordedVishay
- What it is
- ESD protection diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 4-Line BUS-Port ESD Protection
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
VESD05A1B-HD1ESD protection diode, VishayESD protection diodeNot recordedVishay
- What it is
- ESD protection diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD Protection Diode in LLP1006-2L
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
WS7808QM-14WillsemiNot recordedNot recordedWillsemi
- What it is
- Not recorded
- Maker
- Willsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
7WB3126CMXonsemiNot recordedNot recordedonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: 2-Bit bus switch
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
ESDAVLC6-1BF42 pins, STMicroelectronicsNot recorded2 pinsSTMicroelectronics
- What it is
- Not recorded
- Maker
- STMicroelectronics
- Package
- Not recorded
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: This part.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.
1 identification has been run against this marking.