Skip to content

SMD code D16

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 30 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • AZ23C11SOT-23Zener diode, 3 pins, PanjitZener diodeSOT-233 pinsPanjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    11V, 300mW, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • AZ23C11-AUSOT-23Zener diode, 3 pins, PanjitZener diodeSOT-233 pinsPanjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • KIC77D16MSOT-23Voltage supervisor, 3 pins, KECVoltage supervisorSOT-233 pinsKEC
    What it is
    Voltage supervisor
    Maker
    KEC
    Package
    SOT-23
    Pins
    3
    Details
    CMOS system reset IC with delay time, 1.6 V detection
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • KIC77D16TSOT-23Voltage supervisor, 3 pins, KECVoltage supervisorSOT-233 pinsKEC
    What it is
    Voltage supervisor
    Maker
    KEC
    Package
    SOT-23
    Pins
    3
    Details
    CMOS system reset IC with delay time, 1.6 V detection
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • TZT16AWSOT-23Zener diode, 3 pins, Taitron ComponentsZener diodeSOT-233 pinsTaitron Components
    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SOT-23
    Pins
    3
    Details
    SMD Zener Diodes (Three Terminals) - 300mW
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • VESD16A2-03G-G3SOT-323ESD protection diode, 3 pins, VishayESD protection diodeSOT-3233 pinsVishay
    What it is
    ESD protection diode
    Maker
    Vishay
    Package
    SOT-323
    Pins
    3
    Details
    Dual-Line ESD-Protection Diode Array in SOT-323
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 2BZX84C16SOT-23Zener diode, 3 pins, DiotecZener diodeSOT-233 pinsDiotec
    What it is
    Zener diode
    Maker
    Diotec
    Package
    SOT-23
    Pins
    3
    Details
    SMD Planar Zener Diodes
    Source
    An older or alternative marking, from a published code list

    Is it dead? The meter test is below: Zener diode.

  • 2SC1622A-16SOT-233 pins, NEC ElectronicsNot recordedSOT-233 pinsNEC Electronics
    What it is
    Not recorded
    Maker
    NEC Electronics
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn: AF-Amp, 120V, 50mA, 200mW, 110MHz, B=200..400
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 2SC1622AD16SOT-233 pins, RenesasNot recordedSOT-233 pinsRenesas
    What it is
    Not recorded
    Maker
    Renesas
    Package
    SOT-23
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 2SC4180-16SOT-3233 pins, NEC ElectronicsNot recordedSOT-3233 pinsNEC Electronics
    What it is
    Not recorded
    Maker
    NEC Electronics
    Package
    SOT-323
    Pins
    3
    Details
    Si-npn: AF, 120V, 50mA, 150mW, B=200..400, >50MHz
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 2SC4180D16SOT-3233 pins, RenesasNot recordedSOT-3233 pinsRenesas
    What it is
    Not recorded
    Maker
    Renesas
    Package
    SOT-323
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 89N16L-AL4-RSOT-343Voltage supervisor, 4 pins, UnisonicVoltage supervisorSOT-3434 pinsUnisonic
    What it is
    Voltage supervisor
    Maker
    Unisonic
    Package
    SOT-343
    Pins
    4
    Details
    Voltage detector IC: 1.6V±2%, -Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • AD5246SOT-3236 pins, Analog DevicesNot recordedSOT-3236 pinsAnalog Devices
    What it is
    Not recorded
    Maker
    Analog Devices
    Package
    SOT-323
    Pins
    6
    Details
    128-Position I2C-Compatible Digital Resistor
    Source
    Published code list

    Is it dead? The meter test is below: Resistor.

  • AZ23C11-VSOT-23Zener diode, 3 pins, VishayZener diodeSOT-233 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode: Dual, 10.45..11.55V, Zzt=20, Izt=5mA, 300mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • AZZ23C11SOT-233 pins, Diodes IncorporatedNot recordedSOT-233 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-23
    Pins
    3
    Details
    dual ca zener 11V 0.3W
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Resistor

Ohms range, across it, power off.

Working, it reads

Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.

Dead, it reads

  • Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
  • Well above its marked value: drifted high.
  • On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
On the board:
A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
Compare:
The same position on another channel usually carries the same value, and so does the matching part on another board.
Watch for:
A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as D16

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 63 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.