SMD code D6s
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, s, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and D6 was searched.
170 parts are printed D6s
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
SM4006FLCR-CSOD-123FRectifier, 2 pins, SeCoSRectifierSOD-123F2 pinsSeCoS
- What it is
- Rectifier
- Maker
- SeCoS
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
SOD4006SOD-123FRectifier, 2 pins, Galaxy MicroelectronicsRectifierSOD-123F2 pinsGalaxy Microelectronics
- What it is
- Rectifier
- Maker
- Galaxy Microelectronics
- Package
- SOD-123F
- Pins
- 2
- Details
- 1A, 800V, Surface Mount Standard Recovery Rectifiers
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
SOF4006SOD-123FRectifier, 2 pins, Galaxy MicroelectronicsRectifierSOD-123F2 pinsGalaxy Microelectronics
- What it is
- Rectifier
- Maker
- Galaxy Microelectronics
- Package
- SOD-123F
- Pins
- 2
- Details
- 1A, 800V, Surface Mount Standard Recovery Rectifiers
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
TMMBD4148CASOT-23Switching diode, 3 pins, Galaxy MicroelectronicsSwitching diodeSOT-233 pinsGalaxy Microelectronics
- What it is
- Switching diode
- Maker
- Galaxy Microelectronics
- Package
- SOT-23
- Pins
- 3
- Details
- 0.2A,100V, Surface Mount Small Signal Switching Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
TMMBD4148CAWSOT-323Switching diode, 3 pins, Galaxy MicroelectronicsSwitching diodeSOT-3233 pinsGalaxy Microelectronics
- What it is
- Switching diode
- Maker
- Galaxy Microelectronics
- Package
- SOT-323
- Pins
- 3
- Details
- 0.2A,100V, Surface Mount Small Signal Switching Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
TSOD4006SOD-123FRectifier, 2 pins, Galaxy MicroelectronicsRectifierSOD-123F2 pinsGalaxy Microelectronics
- What it is
- Rectifier
- Maker
- Galaxy Microelectronics
- Package
- SOD-123F
- Pins
- 2
- Details
- 1A, 800V, Surface Mount Standard Recovery Rectifiers
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
UDZ6.2BSOD-323Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-3232 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
UDZ6.2B-FLSOD-323Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-3232 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
UDZ6.2B-FL-Q1SOD-323Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-3232 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
UDZ6.2B-Q1SOD-323Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-3232 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
UMD6NSOT-363Digital transistor (resistors built in), 6 pins, JSCJDigital transistor (resistors built in)SOT-3636 pinsJSCJ
- What it is
- Digital transistor (resistors built in)
- Maker
- JSCJ
- Package
- SOT-363
- Pins
- 6
- Details
- Digital transistor (bias resistors built in), PNP NPN
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
2SA1252-6SOT-233 pins, Sanyo ElectricNot recordedSOT-233 pinsSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- SOT-23
- Pins
- 3
- Details
- pnp 60V gp af, hfe 200-400 2SC3141 comp
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SA1687-6SOT-3233 pins, onsemiNot recordedSOT-3233 pinsonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- SOT-323
- Pins
- 3
- Details
- Si-pnp: GP, AF, 60V, 150mA, 150mW, B=200..400, 130MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
3T150ABSMB2 pins, MDE SemiconductorNot recordedSMB2 pinsMDE Semiconductor
- What it is
- Not recorded
- Maker
- MDE Semiconductor
- Package
- SMB
- Pins
- 2
- Details
- Thy-SPD: Vdrm=140V, Vs=180V, Ipp=35A, 40pF
- Source
- Published code list
Is it dead? The meter test is below: This part.
1 more part has no package on record
2SA1687-7Sanyo ElectricNot recordedNot recordedNot recordedSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Si-pnp: GP, AF, 60V, 150mA, 150mW, B=300..600, 130MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.