Skip to content

SMD code D74

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

6 parts are printed D74

Not sure which one you have?

Answer up to 4 quick questions and these 6 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • AZ23C62SOT-23Zener diode, 3 pins, VishayZener diodeSOT-233 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOT-23
    Pins
    3
    Details
    62 V Zener diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • AZ23C62-GSOT-23Zener diode, 3 pins, VishayZener diodeSOT-233 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOT-23
    Pins
    3
    Details
    62 V Zener diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BAT54AWFILMSOT-323Schottky diode, 3 pins, STMicroelectronicsSchottky diodeSOT-3233 pinsSTMicroelectronics
    What it is
    Schottky diode
    Maker
    STMicroelectronics
    Package
    SOT-323
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • AD5162BRMZ2.5MSOP-1010 pins, Analog DevicesNot recordedMSOP-1010 pinsAnalog Devices
    What it is
    Not recorded
    Maker
    Analog Devices
    Package
    MSOP-10
    Pins
    10
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • BA579CSOT-23PIN diode, 3 pins, SGS-Thomson MicroelectronicsPIN diodeSOT-233 pinsSGS-Thomson Microelectronics
    What it is
    PIN diode
    Maker
    SGS-Thomson Microelectronics
    Package
    SOT-23
    Pins
    3
    Details
    PIN diode: Dual, VHF/UHF, 30V, 20mA, Vf<1V(20mA)
    Source
    Published code list

    Is it dead? The meter test is below: PIN diode or varicap.

  • BAT54AWSOT-323Schottky diode, 3 pins, SGS-Thomson MicroelectronicsSchottky diodeSOT-3233 pinsSGS-Thomson Microelectronics
    What it is
    Schottky diode
    Maker
    SGS-Thomson Microelectronics
    Package
    SOT-323
    Pins
    3
    Details
    30 V surface-mount Schottky barrier diode, dual common anode
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as D74

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with D74

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.