Skip to content

SMD code EH-

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

110 parts are printed EH-

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • ABCW66H-HFSOT-23NPN transistor, 3 pins, ComchipNPN transistorSOT-233 pinsComchip
    What it is
    NPN transistor
    Maker
    Comchip
    Package
    SOT-23
    Pins
    3
    Details
    45 V, 0.8 A NPN transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • AMMSZ4716-HFSOD-123Zener diode, 2 pins, ComchipZener diodeSOD-1232 pinsComchip
    What it is
    Zener diode
    Maker
    Comchip
    Package
    SOD-123
    Pins
    2
    Details
    39 V 500 mW zener diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BCW66HSOT-23NPN transistor, 3 pins, InfineonNPN transistorSOT-233 pinsInfineon
    What it is
    NPN transistor
    Maker
    Infineon
    Package
    SOT-23
    Pins
    3
    Details
    75V, 0.8A, General Purpose NPN Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • BZX84B30SOT-23Zener diode, 3 pins, DiotecZener diodeSOT-233 pinsDiotec
    What it is
    Zener diode
    Maker
    Diotec
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX84B30ASOT-23Zener diode, 3 pins, Formosa MicrosemiZener diodeSOT-233 pinsFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX84B30A-Q1SOT-23Zener diode, 3 pins, Formosa MicrosemiZener diodeSOT-233 pinsFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX84C4V3WSOT-323Zener diode, 3 pins, Formosa MicrosemiZener diodeSOT-3233 pinsFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOT-323
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX84C4V3W-Q1SOT-323Zener diode, 3 pins, Formosa MicrosemiZener diodeSOT-3233 pinsFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOT-323
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX585-B33SOD-523Zener diode, 2 pins, NexperiaZener diodeSOD-5232 pinsNexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-523
    Pins
    2
    Pinout
    • 1 cathode
    • 2 anode
    Details
    33 V ±2% voltage regulator (Zener) diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • FP6311SDBSOT-563DC-DC converter, 6 pins, FitipowerDC-DC converterSOT-5636 pinsFitipower
    What it is
    DC-DC converter
    Maker
    Fitipower
    Package
    SOT-563
    Pins
    6
    Details
    High Efficiency 5.5V 1A Synchronous Step Down Converter
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • GSBCW66-HSOT-23NPN transistor, 3 pins, Good-ArkNPN transistorSOT-233 pinsGood-Ark
    What it is
    NPN transistor
    Maker
    Good-Ark
    Package
    SOT-23
    Pins
    3
    Details
    NPN transistor, 45 V, 0.8 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • GSMMSZ4716TSOD-523Zener diode, 2 pins, Good-ArkZener diodeSOD-5232 pinsGood-Ark
    What it is
    Zener diode
    Maker
    Good-Ark
    Package
    SOD-523
    Pins
    2
    Details
    Zener diode, VZ 39 V, 0.2 W
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • LBAS70-05LT1GSOT-23Schottky diode, 3 pins, LRCSchottky diodeSOT-233 pinsLRC
    What it is
    Schottky diode
    Maker
    LRC
    Package
    SOT-23
    Pins
    3
    Details
    Schottky diode, VR 70 V, IF 0.07 A, VF Max 0.41 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • 2 more parts have no package on record
    • DBTC-9-4LX+RF coupler, Mini-CircuitsRF couplerNot recordedNot recordedMini-Circuits
      What it is
      RF coupler
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      RF directional coupler, 5-1000 MHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: This part.

    • FDZ661PZP-channel MOSFET, onsemiP-channel MOSFETNot recordedNot recordedonsemi
      What it is
      P-channel MOSFET
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      P-Channel 1.5 V Specified PowerTrench Thin WL-CSP MOSFET
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: P-channel MOSFET.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

NPN transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

P-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as EH-

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with EH-

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 267 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.