  • Z1SMA27SMAZener diode, 2 pins, Taitron ComponentsZener diode2 pinsTaitron Components
    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SMA
    Pins
    2
    Details
    SMD Zener Diodes (Two Terminals) - 1W
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • Z1SMA-27SMA2 pins, FagNot recorded2 pinsFag
    What it is
    Not recorded
    Maker
    Fag
    Package
    SMA
    Pins
    2
    Details
    Z-diode: 27V±5%, 1,3W
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • 13 more parts have no package on record. Nothing rules them out, so they stay.
    • DBTC-12-4X+RF coupler, Mini-CircuitsRF couplerNot recordedMini-Circuits
      What it is
      RF coupler
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      RF directional coupler, 5-1000 MHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: This part.

    • NCP161BMX350LDO regulator, onsemiLDO regulatorNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LDO Regulator for RF and Analog Circuits - Ultra-Low Noise and High PSRR
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • 2SD27033 pins, ROHMNot recorded3 pinsROHM
      What it is
      Not recorded
      Maker
      ROHM
      Package
      Not recorded
      Pins
      3
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • BD4858FVEVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 5,8V, Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD4858GVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 5,8V, Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5109C45ANVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.5V±2%, +Reset PPO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5127C45KNRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.5V±0.8%, +Reset PPO, -MR, 800ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5127N46ENRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.6V±0.8%, -Reset ODO, -MR, 800ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • RP300K23DC2Voltage supervisor, RicohVoltage supervisorNot recordedRicoh
      What it is
      Voltage supervisor
      Maker
      Ricoh
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.32V±1%, +Reset PPO, -MR, Rdt=200ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • RP602Z360CDC-DC converter, RicohDC-DC converterNot recordedRicoh
      What it is
      DC-DC converter
      Maker
      Ricoh
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM/VFM B-boost, 3.6V±1.5%, 1.5A, 2.6MHz, +CE, CL, Reset-pr.
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • SS1030LHEWSSchottky diode, PanjitSchottky diodeNot recordedPanjit
      What it is
      Schottky diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Diode: SBR, 30V, 1A, Vf<0.39V(1A)
      Source
      Published code list

      Is it dead? The meter test is below: Schottky diode.

    • XC6109C45ANVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 4,5V, Reset Push-pull output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6119C45ANRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.5V±2%, -Reset PPO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.