87 parts are printed FC-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
SD18CL-CSOD-323ESD protection diode, 2 pins, SeCoSESD protection diodeSOD-3232 pinsSeCoS
- What it is
- ESD protection diode
- Maker
- SeCoS
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
TAB18LCSOD-323ESD protection diode, 2 pins, RectronESD protection diodeSOD-3232 pinsRectron
- What it is
- ESD protection diode
- Maker
- Rectron
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Z1SMA3V9SMAZener diode, 2 pins, Taitron ComponentsZener diodeSMA2 pinsTaitron Components
- What it is
- Zener diode
- Maker
- Taitron Components
- Package
- SMA
- Pins
- 2
- Details
- SMD Zener Diodes (Two Terminals) - 1W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
2SC2619-CSOT-23NPN transistor, 3 pins, RenesasNPN transistorSOT-233 pinsRenesas
- What it is
- NPN transistor
- Maker
- Renesas
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: AF, 100mA, 150mW, B=100..200, 230MHz
- Source
- Published code list
Is it dead? The meter test is below: NPN transistor.
2SC2619CSOT-233 pins, RenesasNot recordedSOT-233 pinsRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- SOT-23
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SC3053-CSOT-233 pins, MitNot recordedSOT-233 pinsMit
- What it is
- Not recorded
- Maker
- Mit
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: GP, AM/FM, 30V, 30mA, 150mW, B=55..110, 200MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SC3438-CSOT-893 pins, MitNot recordedSOT-893 pinsMit
- What it is
- Not recorded
- Maker
- Mit
- Package
- SOT-89
- Pins
- 3
- Details
- Si-npn: AF-Drv, 100V, 500mA, 500mW, B=55..110, 130MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SC4258-CSOT-3233 pins, MitNot recordedSOT-3233 pinsMit
- What it is
- Not recorded
- Maker
- Mit
- Package
- SOT-323
- Pins
- 3
- Details
- Si-npn: HF, AM/FM, 30V, 30mA, 150mW, 200MHz, B=55..110
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SC5384-CSOT-4163 pins, Isahaya ElectronicsNot recordedSOT-4163 pinsIsahaya Electronics
- What it is
- Not recorded
- Maker
- Isahaya Electronics
- Package
- SOT-416
- Pins
- 3
- Details
- Si-npn: HF, AM/FM, 30V, 30mA, 125mW, 200MHz, B=55..110
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SC5566SOT-893 pins, Sanyo ElectricNot recordedSOT-893 pinsSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- SOT-89
- Pins
- 3
- Details
- npn DC conv comp 2SA2013
- Source
- Published code list
Is it dead? The meter test is below: This part.
5 more parts have no package on record
RQ6P015SPP-channel MOSFET, ROHMP-channel MOSFETNot recordedNot recordedROHM
- What it is
- P-channel MOSFET
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Pch -100V -1.5A Small Signal MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
TCM2-33X-3+RF transformer, Mini-CircuitsRF transformerNot recordedNot recordedMini-Circuits
- What it is
- RF transformer
- Maker
- Mini-Circuits
- Package
- Not recorded
- Pins
- Not recorded
- Details
- RF transformer, 30-3000 MHz
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
TCM2-33X+RF transformer, Mini-CircuitsRF transformerNot recordedNot recordedMini-Circuits
- What it is
- RF transformer
- Maker
- Mini-Circuits
- Package
- Not recorded
- Pins
- Not recorded
- Details
- RF transformer, 30-3000 MHz
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
VS12VBA1HSESD protection diode, ROHMESD protection diodeNot recordedNot recordedROHM
- What it is
- ESD protection diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Transient Voltage Suppressor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
74AUC1G04GWNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Single inverter
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
NPN transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.