Skip to content

SMD code FQ

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 2SA1037SOT-23PNP transistor, 3 pins, JSCJPNP transistorSOT-233 pinsJSCJ
    What it is
    PNP transistor
    Maker
    JSCJ
    Package
    SOT-23
    Pins
    3
    Details
    Bipolar transistor, 50 V, 0.15 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • 2SA1037-QSOT-23PNP transistor, 3 pins, Galaxy MicroelectronicsPNP transistorSOT-233 pinsGalaxy Microelectronics
    What it is
    PNP transistor
    Maker
    Galaxy Microelectronics
    Package
    SOT-23
    Pins
    3
    Details
    -50V, -0.15A, General Purpose PNP Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • 2SA1037/AK-QSOT-23Transistor, 3 pins, YFWTransistorSOT-233 pinsYFW
    What it is
    Transistor
    Maker
    YFW
    Package
    SOT-23
    Pins
    3
    Details
    Bipolar transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Bipolar transistor.

  • 2SA1037AKT146QSOT-23PNP transistor, 3 pins, HXYPNP transistorSOT-233 pinsHXY
    What it is
    PNP transistor
    Maker
    HXY
    Package
    SOT-23
    Pins
    3
    Details
    Bipolar transistor, 50 V, 0.15 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • 2SA1037KSOT-23PNP transistor, 3 pins, JSCJPNP transistorSOT-233 pinsJSCJ
    What it is
    PNP transistor
    Maker
    JSCJ
    Package
    SOT-23
    Pins
    3
    Details
    Bipolar transistor, PNP
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • 2SA1576A-QSOT-323PNP transistor, 3 pins, Galaxy MicroelectronicsPNP transistorSOT-3233 pinsGalaxy Microelectronics
    What it is
    PNP transistor
    Maker
    Galaxy Microelectronics
    Package
    SOT-323
    Pins
    3
    Details
    -50V, -0.15A, General Purpose PNP Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • 2SA1576AQSOT-323PNP transistor, 3 pins, HXYPNP transistorSOT-3233 pinsHXY
    What it is
    PNP transistor
    Maker
    HXY
    Package
    SOT-323
    Pins
    3
    Details
    Bipolar transistor, 50 V, 0.15 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • 2SA1774-QSOT-523PNP transistor, 3 pins, Galaxy MicroelectronicsPNP transistorSOT-5233 pinsGalaxy Microelectronics
    What it is
    PNP transistor
    Maker
    Galaxy Microelectronics
    Package
    SOT-523
    Pins
    3
    Details
    -50V, -0.15A, General Purpose PNP Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • 2SA2029SOT-723PNP transistor, 3 pins, JSCJPNP transistorSOT-7233 pinsJSCJ
    What it is
    PNP transistor
    Maker
    JSCJ
    Package
    SOT-723
    Pins
    3
    Details
    Bipolar transistor, PNP
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • 2SA2029-QSOT-723PNP transistor, 3 pins, Galaxy MicroelectronicsPNP transistorSOT-7233 pinsGalaxy Microelectronics
    What it is
    PNP transistor
    Maker
    Galaxy Microelectronics
    Package
    SOT-723
    Pins
    3
    Details
    -50V, -0.15A, General Purpose PNP Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • AZ5125-01HSOD-523ESD protection diode, 2 pins, UMWESD protection diodeSOD-5232 pinsUMW
    What it is
    ESD protection diode
    Maker
    UMW
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • FMBTSA1037QSOT-23PNP transistor, 3 pins, Formosa MicrosemiPNP transistorSOT-233 pinsFormosa Microsemi
    What it is
    PNP transistor
    Maker
    Formosa Microsemi
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • H2SA1037AKT146QSOT-23PNP transistor, 3 pins, HXYPNP transistorSOT-233 pinsHXY
    What it is
    PNP transistor
    Maker
    HXY
    Package
    SOT-23
    Pins
    3
    Details
    Bipolar transistor, 50 V, 0.15 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • L2SA1037AKQLT1GSOT-23PNP transistor, 3 pins, LRCPNP transistorSOT-233 pinsLRC
    What it is
    PNP transistor
    Maker
    LRC
    Package
    SOT-23
    Pins
    3
    Details
    Bipolar transistor, PNP, IC 150 mA, VCEO 50 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

  • L2SA1576AQT1GSOT-323PNP transistor, 3 pins, LRCPNP transistorSOT-3233 pinsLRC
    What it is
    PNP transistor
    Maker
    LRC
    Package
    SOT-323
    Pins
    3
    Details
    Bipolar transistor, PNP, IC 150 mA, VCEO 50 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PNP transistor.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

PNP transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as FQ

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 3 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.