Skip to content

SMD code G16

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

10 parts are printed G16

Not sure which one you have?

Answer up to 4 quick questions and these 10 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BZG03C16SMAZener diode, 2 pins, Galaxy MicroelectronicsZener diodeSMA2 pinsGalaxy Microelectronics
    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SMA
    Pins
    2
    Details
    16V, 5%, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • TBZG03C16SMAZener diode, 2 pins, Galaxy MicroelectronicsZener diodeSMA2 pinsGalaxy Microelectronics
    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SMA
    Pins
    2
    Details
    16V, 5%, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • 2SK1590SOT-233 pins, NEC ElectronicsNot recordedSOT-233 pinsNEC Electronics
    What it is
    Not recorded
    Maker
    NEC Electronics
    Package
    SOT-23
    Pins
    3
    Details
    n-MOS*-e: V-MOS, LogL, 60V, ±0,2A, <3Ω
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • BZG03-C16SMAZener diode, 2 pins, Galaxy MicroelectronicsZener diodeSMA2 pinsGalaxy Microelectronics
    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SMA
    Pins
    2
    Details
    Z-diode: 16V±5%, Izt=25mA, Zzt=6Ω, 1,25W
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • KIC73A16TSOT-23Voltage supervisor, 3 pins, KECVoltage supervisorSOT-233 pinsKEC
    What it is
    Voltage supervisor
    Maker
    KEC
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 1.6V±1%, -Reset PPO, Rdt=240ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • LD6969GDAW-16WSONLDO regulator, LeadtrendLDO regulatorWSONNot recordedLeadtrend
    What it is
    LDO regulator
    Maker
    Leadtrend
    Package
    WSON
    Pins
    Not recorded
    Details
    Linear voltage regulator IC: LDO, 1.6V±2%, 100mA, -CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • STPS160USMBSchottky diode, 2 pins, STMicroelectronicsSchottky diodeSMB2 pinsSTMicroelectronics
    What it is
    Schottky diode
    Maker
    STMicroelectronics
    Package
    SMB
    Pins
    2
    Details
    Diode: SBR, 60V, 1A, Vf<0.55V(1A)
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

  • XC9217A166MSOT-23-5DC-DC converter, 5 pins, TorexDC-DC converterSOT-23-55 pinsTorex
    What it is
    DC-DC converter
    Maker
    Torex
    Package
    SOT-23-5
    Pins
    5
    Details
    DC/DC voltage converter IC: PWM-PWM/PFM st-dwn, 1.6V±2%, 500mA, 600KHz, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 2 more parts have no package on record
    • 2SK1590A3 pins, RenesasNot recordedNot recorded3 pinsRenesas
      What it is
      Not recorded
      Maker
      Renesas
      Package
      Not recorded
      Pins
      3
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • KIC73A16MVoltage supervisor, KECVoltage supervisorNot recordedNot recordedKEC
      What it is
      Voltage supervisor
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.6V±1%, -Reset PPO, Rdt=240ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as G16

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 2 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.