Skip to content

SMD code G4p

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

The last letter, p, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and G4 was searched.

148 parts are printed G4p

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • MBT35200MT1GSOT-23-66 pins, onsemiNot recordedSOT-23-66 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    SOT-23-6
    Pins
    6
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • MMBZ5229BTSOT-5233 pins, Diodes IncorporatedNot recordedSOT-5233 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-523
    Pins
    3
    Details
    Z-diode: 4,3V±5%, Zzt=22Ω, 150mW
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • P1100SAASMA2 pins, MDE SemiconductorNot recordedSMA2 pinsMDE Semiconductor
    What it is
    Not recorded
    Maker
    MDE Semiconductor
    Package
    SMA
    Pins
    2
    Details
    Thyristor surge protector: Vdrm=90V, Vs=130V, Ipp=35A(1ms), Bidir.
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • PDTA113EMSOT-8833 pins, NXPNot recordedSOT-8833 pinsNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    SOT-883
    Pins
    3
    Details
    equivalent PDTA113ES
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • PMEG4010BEVSOT-563Schottky diode, 6 pins, NXPSchottky diodeSOT-5636 pinsNXP
    What it is
    Schottky diode
    Maker
    NXP
    Package
    SOT-563
    Pins
    6
    Details
    Diode: SBR, 40V, 1A, Vf=0.54V(1A), 43pF
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

  • PZU2.7BSOD-323Zener diode, 2 pins, NXPZener diodeSOD-3232 pinsNXP
    What it is
    Zener diode
    Maker
    NXP
    Package
    SOD-323
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • R1111N341BSOT-23-55 pins, Nisshinbo Micro DevicesNot recordedSOT-23-55 pinsNisshinbo Micro Devices
    What it is
    Not recorded
    Maker
    Nisshinbo Micro Devices
    Package
    SOT-23-5
    Pins
    5
    Details
    VR-IC: LDO, LN, CE, 3.4V±2%, 200mA
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • R1140Q341DSOT-1434 pins, Nisshinbo Micro DevicesNot recordedSOT-1434 pinsNisshinbo Micro Devices
    What it is
    Not recorded
    Maker
    Nisshinbo Micro Devices
    Package
    SOT-143
    Pins
    4
    Details
    VR-IC: LDO, CE, auto discharge, 3.4V±2%, 120mA
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • R3114Q211CSOT-343Voltage supervisor, 4 pins, RicohVoltage supervisorSOT-3434 pinsRicoh
    What it is
    Voltage supervisor
    Maker
    Ricoh
    Package
    SOT-343
    Pins
    4
    Details
    Voltage detector IC: 2.1V±0.8%, -Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • R3118K201CDFNVoltage supervisor, RicohVoltage supervisorDFNNot recordedRicoh
    What it is
    Voltage supervisor
    Maker
    Ricoh
    Package
    DFN
    Pins
    Not recorded
    Details
    Voltage detector IC: 2.0V±1.5%, -Reset PPO, Sense
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 5 more parts have no package on record
    • MIC5381-1.8/1.2YFTLDO regulator, MicrelLDO regulatorNot recordedNot recordedMicrel
      What it is
      LDO regulator
      Maker
      Micrel
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, Dual out, Vo1/Vo2=1.8V/1.2V±2%, 150mA, +CE, CL
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • NC7SV14LFairchild SemiconductorNot recordedNot recordedNot recordedFairchild Semiconductor
      What it is
      Not recorded
      Maker
      Fairchild Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Inverter with Schmitt-trigger input
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • R1131D141ANisshinbo Micro DevicesNot recordedNot recordedNot recordedNisshinbo Micro Devices
      What it is
      Not recorded
      Maker
      Nisshinbo Micro Devices
      Package
      Not recorded
      Pins
      Not recorded
      Details
      VR-IC: LDO, CE, 1.4V±2%, 300mA
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • R1160D241BNisshinbo Micro DevicesNot recordedNot recordedNot recordedNisshinbo Micro Devices
      What it is
      Not recorded
      Maker
      Nisshinbo Micro Devices
      Package
      Not recorded
      Pins
      Not recorded
      Details
      VR-IC: LDO, CE, 2,4V±2%, 200mA
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • R3113D341CNisshinbo Micro DevicesNot recordedNot recordedNot recordedNisshinbo Micro Devices
      What it is
      Not recorded
      Maker
      Nisshinbo Micro Devices
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 3.4V, -Reset, Push-pull output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.