SMD code GBx
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, x, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and GB was searched.
69 parts are printed GBx
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
BZT52H-A12SOD-123FZener diode, 2 pins, NexperiaZener diodeSOD-123F2 pinsNexperia
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
KDZV3.6BSOD-123FZener diode, 2 pins, ROHMZener diodeSOD-123F2 pinsROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
KDZVTF3.6BSOD-123FZener diode, 2 pins, ROHMZener diodeSOD-123F2 pinsROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- SOD-123F
- Pins
- 2
- Details
- Zener Diode (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LESD8D5.0BT5GSOD-882ESD protection diode, 2 pins, LRCESD protection diodeSOD-8822 pinsLRC
- What it is
- ESD protection diode
- Maker
- LRC
- Package
- SOD-882
- Pins
- 2
- Details
- ESD protection diode, VRWM 5 V, IR @VRWM 1 μA, VBR Min 5.6 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
NCX2222DPTSSOP-8Comparator, 8 pins, NXPComparatorTSSOP-88 pinsNXP
- What it is
- Comparator
- Maker
- NXP
- Package
- TSSOP-8
- Pins
- 8
- Details
- Low voltage comparator; open-drain output
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
NX3020NAKVSOT-563Dual N-channel MOSFET, 6 pins, NexperiaDual N-channel MOSFETSOT-5636 pinsNexperia
- What it is
- Dual N-channel MOSFET
- Maker
- Nexperia
- Package
- SOT-563
- Pins
- 6
- Details
- 30 V, 200 mA dual N-channel Trench MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET pair.
PP0300SASMBTVS thyristor, 2 pins, ProTek DevicesTVS thyristorSMB2 pinsProTek Devices
- What it is
- TVS thyristor
- Maker
- ProTek Devices
- Package
- SMB
- Pins
- 2
- Details
- Thyristor Surge Suppressor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
UFZV9.1BSOD-323Zener diode, 2 pins, ROHMZener diodeSOD-3232 pinsROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
7 more parts have no package on record
NCX2222GFComparator, 8 pins, NXPComparatorNot recorded8 pinsNXP
- What it is
- Comparator
- Maker
- NXP
- Package
- Not recorded
- Pins
- 8
- Details
- Low voltage comparator; open-drain output
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
NCX2222GMComparator, 8 pins, NXPComparatorNot recorded8 pinsNXP
- What it is
- Comparator
- Maker
- NXP
- Package
- Not recorded
- Pins
- 8
- Details
- Low voltage comparator; open-drain output
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
NCX2222GTComparator, 8 pins, NXPComparatorNot recorded8 pinsNXP
- What it is
- Comparator
- Maker
- NXP
- Package
- Not recorded
- Pins
- 8
- Details
- Low voltage comparator; open-drain output
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
NCX2222GUComparator, 8 pins, NXPComparatorNot recorded8 pinsNXP
- What it is
- Comparator
- Maker
- NXP
- Package
- Not recorded
- Pins
- 8
- Details
- Low voltage comparator; open-drain output
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
PBZ3.6BZener diode, ROHMZener diodeNot recordedNot recordedROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
RB168VWM-30Schottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky Barrier Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
RB168VWM-30TFSchottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky Barrier Diode (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET pair
Diode range, part lifted. Test drain to source first, then short gate to source and test again. Test each MOSFET on its own pins, as the datasheet's pinout gives them.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as GBx
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 79 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.