  • MAX6315US43D1-TSOT-1434 pins, Analog DevicesNot recorded4 pinsAnalog Devices
    What it is
    Not recorded
    Maker
    Analog Devices
    Package
    SOT-143
    Pins
    4
    Details
    CMOS-IC: Voltage Detector 4.3V, MR, -Reset ODO, 1ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • R1141Q341DSOT-1434 pins, Nisshinbo Micro DevicesNot recorded4 pinsNisshinbo Micro Devices
    What it is
    Not recorded
    Maker
    Nisshinbo Micro Devices
    Package
    SOT-143
    Pins
    4
    Details
    VR-IC: LDO, CE, auto discharge, 3.4V±2%, 120mA
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • 13 more parts have no package on record. Nothing rules them out, so they stay.
    • BAS40LTHSchottky diode, VishaySchottky diodeNot recordedVishay
      What it is
      Schottky diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Small Signal Schottky Diode with TJ max. = 175 °C
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • NCP134AMX120LDO regulator, onsemiLDO regulatorNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      500 mA, Very Low Dropout Bias Rail CMOS Voltage Regulator
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • NCP718BMT500LDO regulator, onsemiLDO regulatorNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage Regulator - Low Dropout, Wide Input Voltage, Low Iq
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • NCV8711BMTW500LDO regulator, onsemiLDO regulatorNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LDO Regulator, 100 mA, 18 V, 1  A I , with PG
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • NCV8718BMT500LDO regulator, onsemiLDO regulatorNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage Regulator - Low Dropout, Low Iq, Wide Input
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • BD48L35GVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage Detector
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD4944FVEVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 4,4V, Reset Push-pull output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD4944GVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 4,4V, Reset Push-pull output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU45L312GVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.1V±1%, -Reset ODO, Rdt=200ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • EMA1001IBPElite Semiconductor Memory TechnologyNot recordedNot recordedElite Semiconductor Memory Technology
      What it is
      Not recorded
      Maker
      Elite Semiconductor Memory Technology
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear IC: APA, BTL, 2..5.5V, 1W(5V/8), shutdown
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • FP6801-26NC8PVoltage supervisor, FitipowerVoltage supervisorNot recordedFitipower
      What it is
      Voltage supervisor
      Maker
      Fitipower
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.6V±2%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • LM4890IBPNational SemiconductorNot recordedNot recordedNational Semiconductor
      What it is
      Not recorded
      Maker
      National Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Lin-IC: AF PA, BTL, 2,2..5,5V, 1,1W(5V/8Ω), shutdown
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • LM4890IBPXTexas InstrumentsNot recordedNot recordedTexas Instruments
      What it is
      Not recorded
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Lin-IC: AF PA, BTL, 2,2..5,5V, 1,1W(5V/8Ω), shutdown
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as GE

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.