Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

25 parts are printed GGT

Not sure which one you have?

Answer up to 4 quick questions and these 25 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 1SMC78ASMCTVS diode, 2 pins, onsemiTVS diodeSMC2 pinsonsemi
    What it is
    TVS diode
    Maker
    onsemi
    Package
    SMC
    Pins
    2
    Details
    TVS: 78V, 11.4A, 1500W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 15SMBJ78ASMBTVS diode, 2 pins, UN SemiconductorTVS diodeSMB2 pinsUN Semiconductor
    What it is
    TVS diode
    Maker
    UN Semiconductor
    Package
    SMB
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=78.0V, Vbr=86.70..95.80V, Ipp=11.9A, 1500W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • CD214C-T78ASMCTVS diode, 2 pins, BournsTVS diodeSMC2 pinsBourns
    What it is
    TVS diode
    Maker
    Bourns
    Package
    SMC
    Pins
    2
    Details
    TVS: 78V, 11.4A, 1500W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • EC76SMCJ78ASMCTVS diode, 2 pins, E-CMOSTVS diodeSMC2 pinsE-CMOS
    What it is
    TVS diode
    Maker
    E-CMOS
    Package
    SMC
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=78V, Vbr=86.7..99.7V, 11.9A, 1500W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMCJ43ASMCTVS diode, 2 pins, RFE InternationalTVS diodeSMC2 pinsRFE International
    What it is
    TVS diode
    Maker
    RFE International
    Package
    SMC
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMCJ90ASMCTVS diode, 2 pins, Ruilong Yuan ElectronicsTVS diodeSMC2 pinsRuilong Yuan Electronics
    What it is
    TVS diode
    Maker
    Ruilong Yuan Electronics
    Package
    SMC
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • TFMCJ78ASMC2 pins, RectronNot recordedSMC2 pinsRectron
    What it is
    Not recorded
    Maker
    Rectron
    Package
    SMC
    Pins
    2
    Details
    TVS: 78V, 11.9A, 1500W (1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • TV15C780JSMC2 pins, ComchipNot recordedSMC2 pinsComchip
    What it is
    Not recorded
    Maker
    Comchip
    Package
    SMC
    Pins
    2
    Details
    TVS: 78V, 5%, 11.4A, 1500W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • TV15C780J-GSMCTVS diode, 2 pins, ComchipTVS diodeSMC2 pinsComchip
    What it is
    TVS diode
    Maker
    Comchip
    Package
    SMC
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=78.0V, Vbr=86.70..95.80V, Ipp=11.90A, 1500W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 1 more part has no package on record
    • 1SMC78AT3TVS diode, onsemiTVS diodeNot recordedNot recordedonsemi
      What it is
      TVS diode
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient voltage supressor: Vbr=86.7..95.8V, Vrwm=78V, 11.9A, 1500W(1ms)
      Source
      Published code list

      Is it dead? The meter test is below: TVS or ESD protection diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.