SMD code GK-
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
48 parts are printed GK-
Not sure which one you have?
Answer up to 4 quick questions and these 48 parts are ranked, with a meter test that settles it. It works on a dead part too.
BZT52H-A27SOD-123FZener diode, 2 pins, NexperiaZener diodeSOD-123F2 pinsNexperia
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LBAS70-06LT1GSOT-23Schottky diode, 3 pins, LRCSchottky diodeSOT-233 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Schottky diode, VR 70 V, IF 0.07 A, VF Max 0.75 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
PP2600SASMBTVS thyristor, 2 pins, ProTek DevicesTVS thyristorSMB2 pinsProTek Devices
- What it is
- TVS thyristor
- Maker
- ProTek Devices
- Package
- SMB
- Pins
- 2
- Details
- Thyristor Surge Suppressor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
S-LBAS70-06LT1GSOT-23Schottky diode, 3 pins, LRCSchottky diodeSOT-233 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Schottky diode, VR 70 V, IF 0.07 A, VF Max 0.75 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
SMBJ400CASMBTVS diode, 2 pins, Good-ArkTVS diodeSMB2 pinsGood-Ark
- What it is
- TVS diode
- Maker
- Good-Ark
- Package
- SMB
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
TPS7A0320PDQNX2SONLDO regulator, 4 pins, Texas InstrumentsLDO regulatorX2SON4 pinsTexas Instruments
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- X2SON
- Pins
- 4
- Details
- Nanopower IQ, 200nA, 200mA, Low-Dropout Voltage Regulator With Fast Transient Response
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
WL2863D25-4DFNLDO regulator, WillsemiLDO regulatorDFNNot recordedWillsemi
- What it is
- LDO regulator
- Maker
- Willsemi
- Package
- DFN
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
2SD1615-KSOT-893 pins, NEC ElectronicsNot recordedSOT-893 pinsNEC Electronics
- What it is
- Not recorded
- Maker
- NEC Electronics
- Package
- SOT-89
- Pins
- 3
- Details
- Si-npn: AF-Amp, Sw, 60V, 1A, 2W, 160MHz, B=300..600
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SD1615GKSOT-893 pins, RenesasNot recordedSOT-893 pinsRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- SOT-89
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SK2969SOT-233 pins, Sanyo ElectricNot recordedSOT-233 pinsSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- SOT-23
- Pins
- 3
- Details
- n-MOS*-e: V-MOS, LogL, 30V, 0,8A, <0,52Ω, 20/50ns
- Source
- Published code list
Is it dead? The meter test is below: This part.
3T260ASMB2 pins, MDE SemiconductorNot recordedSMB2 pinsMDE Semiconductor
- What it is
- Not recorded
- Maker
- MDE Semiconductor
- Package
- SMB
- Pins
- 2
- Details
- Thy-SPD: Vdrm=220V, Vs=300V, Ipp=50A, 30pF
- Source
- Published code list
Is it dead? The meter test is below: This part.
4 more parts have no package on record
NCP134AMX180LDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
- What it is
- LDO regulator
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 500 mA, Very Low Dropout Bias Rail CMOS Voltage Regulator
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
NCV8186BMN330LDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
- What it is
- LDO regulator
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LDO Regulator - Fast Transient Response, Low Voltage
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
RQ5L045BGN-channel MOSFET, ROHMN-channel MOSFETNot recordedNot recordedROHM
- What it is
- N-channel MOSFET
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Nch 60V 4.5A Power MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
TCM3-452X-1+RF transformer, Mini-CircuitsRF transformerNot recordedNot recordedMini-Circuits
- What it is
- RF transformer
- Maker
- Mini-Circuits
- Package
- Not recorded
- Pins
- Not recorded
- Details
- RF transformer, 20-4000 MHz
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as GK-
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 78 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.