SMD code H4 in SOD-123F
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
13 parts in SOD-123F are printed H4
Not sure which one you have?
Answer up to 4 quick questions and these 41 parts are ranked, with a meter test that settles it. It works on a dead part too.
CURMT104-HFSOD-123FRectifier, 2 pins, ComchipRectifier2 pinsComchip
- What it is
- Rectifier
- Maker
- Comchip
- Package
- SOD-123F
- Pins
- 2
- Details
- 400 V, 1 A rectifier
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FH4SOD-123FRectifier, 2 pins, Good-ArkRectifier2 pinsGood-Ark
- What it is
- Rectifier
- Maker
- Good-Ark
- Package
- SOD-123F
- Pins
- 2
- Details
- Rectifier, 400 V, 1 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
MMSZ5229BSOD-123FZener diode, 2 pins, DiotecZener diode2 pinsDiotec
- What it is
- Zener diode
- Maker
- Diotec
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MMSZ5244A-FLSOD-123FZener diode, 2 pins, Formosa MicrosemiZener diode2 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MMSZ5244BSOD-123FZener diode, 2 pins, Formosa MicrosemiZener diode2 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MMSZ5244B-FLSOD-123FZener diode, 2 pins, Formosa MicrosemiZener diode2 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MMSZ5244B-FL-Q1SOD-123FZener diode, 2 pins, Formosa MicrosemiZener diode2 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MMSZ5244B-Q1SOD-123FZener diode, 2 pins, Formosa MicrosemiZener diode2 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
SEF104FLSOD-123FRectifier, 2 pins, SeCoSRectifier2 pinsSeCoS
- What it is
- Rectifier
- Maker
- SeCoS
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
SOD1H4SOD-123FRectifier, 2 pins, Galaxy MicroelectronicsRectifier2 pinsGalaxy Microelectronics
- What it is
- Rectifier
- Maker
- Galaxy Microelectronics
- Package
- SOD-123F
- Pins
- 2
- Details
- 1A, 300V, 50ns, Surface Mount Fast Recovery Rectifiers
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
SOF1H4SOD-123FRectifier, 2 pins, Galaxy MicroelectronicsRectifier2 pinsGalaxy Microelectronics
- What it is
- Rectifier
- Maker
- Galaxy Microelectronics
- Package
- SOD-123F
- Pins
- 2
- Details
- 1A, 300V, 50ns, Surface Mount Fast Recovery Rectifiers
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
MM1Z5229BSOD-123FZener diode, 2 pins, EIC SemiconductorZener diode2 pinsEIC Semiconductor
- What it is
- Zener diode
- Maker
- EIC Semiconductor
- Package
- SOD-123F
- Pins
- 2
- Details
- Zener diode: 4.09..4.52V, Izt=20mA, Zzt=22, 500mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
MMSZ5244B-FSOD-123FZener diode, 2 pins, Taitron ComponentsZener diode2 pinsTaitron Components
- What it is
- Zener diode
- Maker
- Taitron Components
- Package
- SOD-123F
- Pins
- 2
- Details
- Zener diode: 13.30..14.70V, Izt=9.0mA, 500mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
2 more parts have no package on record. Nothing rules them out, so they stay.
BGH182MRF amplifier (MMIC), InfineonRF amplifier (MMIC)Not recordedInfineon
- What it is
- RF amplifier (MMIC)
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: RF amplifier.
HFCN-3500+RF filter, Mini-CircuitsRF filterNot recordedMini-Circuits
- What it is
- RF filter
- Maker
- Mini-Circuits
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LTCC filter, 3900-9800 MHz
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
RF amplifier
Voltage, board powered, on the output pin that the bias resistor or choke feeds.
Working, it reads
The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.
Dead, it reads
- Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
- Output pin at the full supply voltage: open inside, no current flowing.
- On the board:
- Measured on the board with power on; the bias network is part of the reading.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The figures depend on the part and its bias resistor. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with H4
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 30 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.