Skip to content

SMD code HB in DFN

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 40 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • RS3212-1.5XUTDN4DFNLDO regulator, RunicLDO regulatorRunic
    What it is
    LDO regulator
    Maker
    Runic
    Package
    DFN
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Voltage regulator.

  • R3116K081ADFNVoltage supervisor, RicohVoltage supervisorRicoh
    What it is
    Voltage supervisor
    Maker
    Ricoh
    Package
    DFN
    Pins
    Not recorded
    Details
    Voltage detector IC: 0.8V±0.8%, -Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • UM1560DB-41DFNLDO regulator, Union SemiconductorLDO regulatorUnion Semiconductor
    What it is
    LDO regulator
    Maker
    Union Semiconductor
    Package
    DFN
    Pins
    Not recorded
    Details
    Linear voltage regulator IC: LDO, 4.1V±2%, 200mA, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • 12 more parts have no package on record. Nothing rules them out, so they stay.
    • ESDHB3V3AE1ESD protection diode, JSCJESD protection diodeJSCJ
      What it is
      ESD protection diode
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 3.3 V
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • MM5Z4V7BZener diode, Formosa MicrosemiZener diodeFormosa Microsemi
      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • MM5Z4V7B-Q1Zener diode, Formosa MicrosemiZener diodeFormosa Microsemi
      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • N02V5BT1006ESD protection diode, Formosa MicrosemiESD protection diodeFormosa Microsemi
      What it is
      ESD protection diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • PBZ3.9BZener diode, ROHMZener diodeROHM
      What it is
      Zener diode
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • RB168VWM-40Schottky diode, ROHMSchottky diodeROHM
      What it is
      Schottky diode
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Barrier Diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • RB168VWM-40TFSchottky diode, ROHMSchottky diodeROHM
      What it is
      Schottky diode
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Barrier Diode (AEC-Q101 qualified)
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • 2SC3137ToshibaNot recordedToshiba
      What it is
      Not recorded
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      4
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • 74HC1G02GWNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-input NOR gate
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD48L46GVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage Detector
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU45L462GVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.6V±1%, -Reset ODO, Rdt=200ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4810FVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 1V, -Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as HB

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.