SMD code HC-
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
103 parts are printed HC-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
ACPDV24V-HFSOD-323ESD protection diode, 2 pins, ComchipESD protection diodeSOD-3232 pinsComchip
- What it is
- ESD protection diode
- Maker
- Comchip
- Package
- SOD-323
- Pins
- 2
- Details
- 24 V bidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ACPDV24V0A-HFSOD-323ESD protection diode, 2 pins, ComchipESD protection diodeSOD-3232 pinsComchip
- What it is
- ESD protection diode
- Maker
- Comchip
- Package
- SOD-323
- Pins
- 2
- Details
- 24 V bidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
BAV23SOT-23Switching diode, 3 pins, Formosa MicrosemiSwitching diodeSOT-233 pinsFormosa Microsemi
- What it is
- Switching diode
- Maker
- Formosa Microsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BAV23ISOT-23Switching diode, 3 pins, DiotecSwitching diodeSOT-233 pinsDiotec
- What it is
- Switching diode
- Maker
- Diotec
- Package
- SOT-23
- Pins
- 3
- Details
- SMD Small Signal Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BV24CSOD-323ESD protection diode, 2 pins, YFWESD protection diodeSOD-3232 pinsYFW
- What it is
- ESD protection diode
- Maker
- YFW
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
BZX585-C20SOD-523Zener diode, 2 pins, NexperiaZener diodeSOD-5232 pinsNexperia
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-523
- Pins
- 2
- Pinout
- 1 cathode
- 2 anode
- Details
- 20 V approx. ±5% voltage regulator (Zener) diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
CPDV24V0-HFSOD-323ESD protection diode, 2 pins, ComchipESD protection diodeSOD-3232 pinsComchip
- What it is
- ESD protection diode
- Maker
- Comchip
- Package
- SOD-323
- Pins
- 2
- Details
- 24 V bidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESDA3L24CBSOD-323ESD protection diode, 2 pins, Formosa MicrosemiESD protection diodeSOD-3232 pinsFormosa Microsemi
- What it is
- ESD protection diode
- Maker
- Formosa Microsemi
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
GBLC24CSOD-323ESD protection diode, 2 pins, YFWESD protection diodeSOD-3232 pinsYFW
- What it is
- ESD protection diode
- Maker
- YFW
- Package
- SOD-323
- Pins
- 2
- Details
- Ultra Low Capacitance TVS Array
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
GBLC24C-HFSOD-323ESD protection diode, 2 pins, ComchipESD protection diodeSOD-3232 pinsComchip
- What it is
- ESD protection diode
- Maker
- Comchip
- Package
- SOD-323
- Pins
- 2
- Details
- 24 V bidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
GBLC24CISOD-323ESD protection diode, 2 pins, ProTek DevicesESD protection diodeSOD-3232 pinsProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- SOD-323
- Pins
- 2
- Details
- Ultra Low Capacitance TVS Array
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
GSLC24B006SOD-323ESD protection diode, 2 pins, Good-ArkESD protection diodeSOD-3232 pinsGood-Ark
- What it is
- ESD protection diode
- Maker
- Good-Ark
- Package
- SOD-323
- Pins
- 2
- Details
- ESD protection diode, VRWM 24 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
GSMMBD3004SOT-23Switching diode, 3 pins, Good-ArkSwitching diodeSOT-233 pinsGood-Ark
- What it is
- Switching diode
- Maker
- Good-Ark
- Package
- SOT-23
- Pins
- 3
- Details
- Switching diode, 300 V, 225 mA
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
KDZV39ASOD-123FZener diode, 2 pins, ROHMZener diodeSOD-123F2 pinsROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
KDZVTF39ASOD-123FZener diode, 2 pins, ROHMZener diodeSOD-123F2 pinsROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- SOD-123F
- Pins
- 2
- Details
- Zener Diode (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as HC-
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 2 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.