15 parts have no package on record. Nothing rules them out, so they stay.

  • SMF3.0ATVS diode, Taitron ComponentsTVS diodeTaitron Components
    What it is
    TVS diode
    Maker
    Taitron Components
    Package
    Not recorded
    Pins
    Not recorded
    Details
    SMD TVS - 200W
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 74HC1GU04GWNXPNot recordedNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Single unbuffered inverter
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BD48L48GVoltage supervisor, ROHMVoltage supervisorROHM
    What it is
    Voltage supervisor
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage Detector
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BU45L482GVoltage supervisor, ROHMVoltage supervisorROHM
    What it is
    Voltage supervisor
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 4.8V±1%, -Reset ODO, Rdt=200ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BU4812FVoltage supervisor, ROHMVoltage supervisorROHM
    What it is
    Voltage supervisor
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS-IC: Voltage Detector 1,2V, -Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BU4812FWEVoltage supervisor, ROHMVoltage supervisorROHM
    What it is
    Voltage supervisor
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS-IC: Voltage Detector 1,2V, -Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BU4812GVoltage supervisor, ROHMVoltage supervisorROHM
    What it is
    Voltage supervisor
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS-IC: Voltage Detector 1,2V, -Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • IXD5127C22BNRVoltage supervisor, IXYSVoltage supervisorIXYS
    What it is
    Voltage supervisor
    Maker
    IXYS
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 2.2V±0.8%, -Reset PPO, -MR, 100ms Rt delay
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • IXD5127N22GNRVoltage supervisor, IXYSVoltage supervisorIXYS
    What it is
    Voltage supervisor
    Maker
    IXYS
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Voltage detector IC: 2.2V±0.8%, +Reset ODO, -MR, 100ms Rt delay
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • KRA554FKECNot recordedKEC
    What it is
    Not recorded
    Maker
    KEC
    Package
    Not recorded
    Pins
    Not recorded
    Details
    PNP transistor: Dual, Sw, 20V, 50mA, 50mW, R1/R2=47k/47k
    Source
    Published code list

    Is it dead? The meter test is below: Bipolar transistor.

  • MUH1PDRectifier, VishayRectifierVishay
    What it is
    Rectifier
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Diode: Rectifier, 200V, 1A, Vf<0.9V(1A)
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • RP602Z405DDC-DC converter, RicohDC-DC converterRicoh
    What it is
    DC-DC converter
    Maker
    Ricoh
    Package
    Not recorded
    Pins
    Not recorded
    Details
    DC/DC voltage converter IC: PWM/VFM B-boost, 4.05V±1.5%, 1.5A, 2.6MHz, +CE, Reset-pr.
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • SN74AUP2G06DRYTexas InstrumentsNot recordedTexas Instruments
    What it is
    Not recorded
    Maker
    Texas Instruments
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Dual inverter buffer/driver (ODO)
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • SN74AUP2G06DSFTexas InstrumentsNot recordedTexas Instruments
    What it is
    Not recorded
    Maker
    Texas Instruments
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: Dual inverter buffer/driver (ODO)
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • UH1PDRectifier, VishayRectifierVishay
    What it is
    Rectifier
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Diode: Rectifier, 200V, 1A, Vf<0.95V(1A)
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.