Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 18 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • RS3212-3.3XUTDN4DFNLDO regulator, RunicLDO regulatorRunic
    What it is
    LDO regulator
    Maker
    Runic
    Package
    DFN
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Voltage regulator.

  • R3116K131ADFNVoltage supervisor, RicohVoltage supervisorRicoh
    What it is
    Voltage supervisor
    Maker
    Ricoh
    Package
    DFN
    Pins
    Not recorded
    Details
    Voltage detector IC: 1.3V±0.8%, -Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 13 more parts have no package on record. Nothing rules them out, so they stay.
    • NCP145AMX105LDO regulator, onsemiLDO regulatoronsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage Regulator, Bias Rail CMOS, Very Low Dropout, 500 mA
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • NCP177BMX150LDO regulator, onsemiLDO regulatoronsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear Voltage Regulator - Fast Transient Response, Enable
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • NCP186BMX300LDO regulator, onsemiLDO regulatoronsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LDO Regulator - Fast Transient Response Low Voltage
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • 2SC2806ToshibaNot recordedToshiba
      What it is
      Not recorded
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      4
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • 74HC1G32GWNXPNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-input OR gate
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD48L51GVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage Detector
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU46L252GVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.5V±1%, -Reset PPO, Rdt=200ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4815FVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 1,5V, -Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4815FWEVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 1,5V, -Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4815GVoltage supervisor, ROHMVoltage supervisorROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 1,5V, -Reset Open drain output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • CFY77-08InfineonNot recordedInfineon
      What it is
      Not recorded
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Details
      20GHz HEMT 0.8dB nf
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • KRA557FKECNot recordedKEC
      What it is
      Not recorded
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      PNP transistor: Dual, Sw, 20V, 50mA, 50mW, R1/R2=10k/47k
      Source
      Published code list

      Is it dead? The meter test is below: Bipolar transistor.

    • LT4ME6.0ATVS diode, Lite-On SemiconductorTVS diodeLite-On Semiconductor
      What it is
      TVS diode
      Maker
      Lite-On Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient voltage supressor: Vrwm=6.0V, Vbr=6.67..7.37V, Ipp=38.8A, 400W(1ms)
      Source
      Published code list

      Is it dead? The meter test is below: TVS or ESD protection diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as HG

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.