SMD code HP in SOD-323
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
4 parts in SOD-323 are printed HP
Not sure which one you have?
Answer up to 4 quick questions and these 33 parts are ranked, with a meter test that settles it. It works on a dead part too.
SMV1281-011LFSOD-323Varicap diode, SkyworksVaricap diodeSkyworks
- What it is
- Varicap diode
- Maker
- Skyworks
- Package
- SOD-323
- Pins
- 2
- Details
- Tuning Varactors
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PIN diode or varicap.
CMDZ3L9SOD-323Zener diodeZener diodeNot recorded
- What it is
- Zener diode
- Maker
- Not recorded
- Package
- SOD-323
- Pins
- 2
- Details
- zener 250mW Iz 0.5mA 3.9V
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
DDZ9696SSOD-323Zener diode, Diodes IncorporatedZener diodeDiodes Incorporated
- What it is
- Zener diode
- Maker
- Diodes Incorporated
- Package
- SOD-323
- Pins
- 2
- Details
- Z-diode: 9,1V±5%, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
PZU20B2SOD-323Zener diode, NXPZener diodeNXP
- What it is
- Zener diode
- Maker
- NXP
- Package
- SOD-323
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
11 more parts have no package on record. Nothing rules them out, so they stay.
MM5Z12VBZener diode, Formosa MicrosemiZener diodeFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM5Z12VB-Q1Zener diode, Formosa MicrosemiZener diodeFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BD48L56GVoltage supervisor, ROHMVoltage supervisorROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage Detector
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BU46L302GVoltage supervisor, ROHMVoltage supervisorROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 3.0V±1%, -Reset PPO, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BU4822FVoltage supervisor, ROHMVoltage supervisorROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 2,2V, -Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BU4822FWEVoltage supervisor, ROHMVoltage supervisorROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 2,2V, -Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BU4822GVoltage supervisor, ROHMVoltage supervisorROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 2,2V, -Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5127C38BNRVoltage supervisor, IXYSVoltage supervisorIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 3.8V±0.8%, -Reset PPO, -MR, 100ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5127N38GNRVoltage supervisor, IXYSVoltage supervisorIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 3.8V±0.8%, +Reset ODO, -MR, 100ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
KDZ12FVYZener diode, KECZener diodeKEC
- What it is
- Zener diode
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode: 11.74..12.24V, Izt=5mA, Zzt=15, 100mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
KRA564FKECNot recordedKEC
- What it is
- Not recorded
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- PNP transistor: Dual, Sw, 20V, 50mA, 50mW, R1=47k
- Source
- Published code list
Is it dead? The meter test is below: Bipolar transistor.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
PIN diode or varicap
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Bipolar transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with HP
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 16 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.