SMD code HR-
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
90 parts are printed HR-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
2SA1036SOT-23PNP transistor, 3 pins, Galaxy MicroelectronicsPNP transistorSOT-233 pinsGalaxy Microelectronics
- What it is
- PNP transistor
- Maker
- Galaxy Microelectronics
- Package
- SOT-23
- Pins
- 3
- Details
- 32V, 0.5A, General Purpose PNP Bipolar Transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
2SA1577-RSOT-323PNP transistor, 3 pins, Galaxy MicroelectronicsPNP transistorSOT-3233 pinsGalaxy Microelectronics
- What it is
- PNP transistor
- Maker
- Galaxy Microelectronics
- Package
- SOT-323
- Pins
- 3
- Details
- -32V, -0.5A, General Purpose PNP Bipolar Transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
6.0SMAJ100CASMATVS diode, 2 pins, Galaxy MicroelectronicsTVS diodeSMA2 pinsGalaxy Microelectronics
- What it is
- TVS diode
- Maker
- Galaxy Microelectronics
- Package
- SMA
- Pins
- 2
- Details
- 100V, 600W, Surface Mount TVS
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ASMF17A-HFSOD-123FTVS diode, 2 pins, ComchipTVS diodeSOD-123F2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SOD-123F
- Pins
- 2
- Details
- 17 V 200 W unidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ATV02W170-HFSOD-123FTVS diode, 2 pins, ComchipTVS diodeSOD-123F2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SOD-123F
- Pins
- 2
- Details
- 17 V 200 W unidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
BZX585-C56SOD-523Zener diode, 2 pins, NexperiaZener diodeSOD-5232 pinsNexperia
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-523
- Pins
- 2
- Pinout
- 1 cathode
- 2 anode
- Details
- 56 V approx. ±5% voltage regulator (Zener) diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
L2SA1036KRLT1GSOT-23PNP transistor, 3 pins, LRCPNP transistorSOT-233 pinsLRC
- What it is
- PNP transistor
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Bipolar transistor, PNP, IC 500 mA, VCEO 32 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
MMBTRC103SSSOT-23Digital transistor (resistors built in), 3 pins, DiotecDigital transistor (resistors built in)SOT-233 pinsDiotec
- What it is
- Digital transistor (resistors built in)
- Maker
- Diotec
- Package
- SOT-23
- Pins
- 3
- Details
- SMD Digital NPN Transistors
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
PTVSHC1RF8VBSOD-123FTVS diode, 2 pins, PrisemiTVS diodeSOD-123F2 pinsPrisemi
- What it is
- TVS diode
- Maker
- Prisemi
- Package
- SOD-123F
- Pins
- 2
- Details
- TVS diode, 8 V working, bidirectional
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
S-L2SA1036KRLT1GSOT-23PNP transistor, 3 pins, LRCPNP transistorSOT-233 pinsLRC
- What it is
- PNP transistor
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Bipolar transistor, PNP, IC 500 mA, VCEO 32 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
SDFL8.0A-CSOD-123FTVS diode, 2 pins, SeCoSTVS diodeSOD-123F2 pinsSeCoS
- What it is
- TVS diode
- Maker
- SeCoS
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMAJ8.0ASMATVS diode, 2 pins, JieJieTVS diodeSMA2 pinsJieJie
- What it is
- TVS diode
- Maker
- JieJie
- Package
- SMA
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
3 more parts have no package on record
MM5Z13VBZener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM5Z13VB-Q1Zener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
RQ7E110AJN-channel MOSFET, ROHMN-channel MOSFETNot recordedNot recordedROHM
- What it is
- N-channel MOSFET
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Nch 30V 11A Middle Power MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
PNP transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as HR-
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with HR-
For a marking with its end worn or burnt off. Each code has a page of its own.
- HRO4
- HR234
- HRG1
- HRH19
- HR10G1
- HR12G1
- HR18G1
- HR33G1
- HR2P2
- HRQ1
- HRZ16
- HR2G4
- HR26
- HRS15
- HRR16
- HR75
- HR44
- HR4Y1
- HR64
- HRA8
- HRY15
- HR242
- HR252
- HR262
- HR1M1
- HRB17
Codes not listed here are printed on 266 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.