SMD code HT in SMB
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
2 parts in SMB are printed HT
Not sure which one you have?
Answer up to 4 quick questions and these 25 parts are ranked, with a meter test that settles it. It works on a dead part too.
Z2SMB-150SMB2 pins, FagNot recorded2 pinsFag
- What it is
- Not recorded
- Maker
- Fag
- Package
- SMB
- Pins
- 2
- Details
- Z-diode: 150V±5%, 2W
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
Z2SMB150SMBZener diode, 2 pins, Fagor ElectronicaZener diode2 pinsFagor Electronica
- What it is
- Zener diode
- Maker
- Fagor Electronica
- Package
- SMB
- Pins
- 2
- Details
- Zener diode: 150V±5%, Izt=5mA, 2W
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
13 more parts have no package on record. Nothing rules them out, so they stay.
RQ5E065AJN-channel MOSFET, ROHMN-channel MOSFETNot recordedROHM
- What it is
- N-channel MOSFET
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Nch 30V 6.5A Small Signal MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
BU46L332GVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 3.3V±1%, -Reset PPO, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BU4826FVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 2,6V, -Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BU4826FWEVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 2,6V, -Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BU4826GVoltage supervisor, ROHMVoltage supervisorNot recordedROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 2,6V, -Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5127C44BNRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.4V±0.8%, -Reset PPO, -MR, 100ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5127N44GNRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.4V±0.8%, +Reset ODO, -MR, 100ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
LT4ME8.5ATVS diode, Lite-On SemiconductorTVS diodeNot recordedLite-On Semiconductor
- What it is
- TVS diode
- Maker
- Lite-On Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Transient voltage supressor: Vrwm=8.5V, Vbr=9.44..10.43V, Ipp=27.7A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
P2SMSJ8.5ATVS diode, YeashinTVS diodeNot recordedYeashin
- What it is
- TVS diode
- Maker
- Yeashin
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Transient voltage supressor: Vrwm=8.5V, Vbr=9.44..10.4V, Ipp=13.9A, 200W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
RP300K46BBVoltage supervisor, RicohVoltage supervisorNot recordedRicoh
- What it is
- Voltage supervisor
- Maker
- Ricoh
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.6V±1%, -Reset ODO, -MR, Rdt=100ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
SMF4L8.5AQTVS diode, Diodes IncorporatedTVS diodeNot recordedDiodes Incorporated
- What it is
- TVS diode
- Maker
- Diodes Incorporated
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Transient voltage supressor: Vrwm=8.5V, Vbr=9.44..10.43V, Ipp=27.7A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
XC6127C44BNRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.4V±0.8%, -Reset PPO, -MR, Rdt=100ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6127N44GNRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.4V±0.8%, +Reset ODO, -MR, Rdt=100ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as HT
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with HT
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 86 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.