SMD code HZ in DFN
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
1 part in DFN is printed HZ
Not sure which one you have?
Answer up to 4 quick questions and these 25 parts are ranked, with a meter test that settles it. It works on a dead part too.
R3116K301ADFNVoltage supervisor, RicohVoltage supervisorRicoh
- What it is
- Voltage supervisor
- Maker
- Ricoh
- Package
- DFN
- Pins
- Not recorded
- Details
- Voltage detector IC: 3.0V±0.8%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
14 more parts have no package on record. Nothing rules them out, so they stay.
MM3Z12VBW-CZener diode, SeCoSZener diodeSeCoS
- What it is
- Zener diode
- Maker
- SeCoS
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM5Z18VBZener diode, Formosa MicrosemiZener diodeFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM5Z18VB-Q1Zener diode, Formosa MicrosemiZener diodeFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
TC1.33-182X-75+RF transformer, Mini-CircuitsRF transformerMini-Circuits
- What it is
- RF transformer
- Maker
- Mini-Circuits
- Package
- Not recorded
- Pins
- Not recorded
- Details
- RF transformer, 5-1800 MHz
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
BU4832FVoltage supervisor, ROHMVoltage supervisorROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 3,2V, -Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BU4832FWEVoltage supervisor, ROHMVoltage supervisorROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 3,2V, -Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BU4832GVoltage supervisor, ROHMVoltage supervisorROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 3,2V, -Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5127C54BNRVoltage supervisor, IXYSVoltage supervisorIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.4V±0.8%, -Reset PPO, -MR, 100ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5127N54GNRVoltage supervisor, IXYSVoltage supervisorIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.4V±0.8%, +Reset ODO, -MR, 100ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
LT4ME11ATVS diode, Lite-On SemiconductorTVS diodeLite-On Semiconductor
- What it is
- TVS diode
- Maker
- Lite-On Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Transient voltage supressor: Vrwm=11V, Vbr=12.2..13.5V, Ipp=22.0A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
P2SMSJ11ATVS diode, YeashinTVS diodeYeashin
- What it is
- TVS diode
- Maker
- Yeashin
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Transient voltage supressor: Vrwm=11V, Vbr=12.2..13.5V, Ipp=11A, 200W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
SMF4L11AQTVS diode, Diodes IncorporatedTVS diodeDiodes Incorporated
- What it is
- TVS diode
- Maker
- Diodes Incorporated
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Transient voltage supressor: Vrwm=11V, Vbr=12.2..13.5V, Ipp=22A, 400W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
XC6119N09ANRVoltage supervisor, TorexVoltage supervisorTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 0.9V±30mV, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6127C54BNRVoltage supervisor, TorexVoltage supervisorTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.4V±0.8%, -Reset PPO, -MR, Rdt=100ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as HZ
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.