SMD code J8 in SOT-89

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 14 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • RT9166A-35CXLSOT-89LDO regulator, 3 pins, RichtekLDO regulator3 pinsRichtek
    What it is
    LDO regulator
    Maker
    Richtek
    Package
    SOT-89
    Pins
    3
    Details
    VR-IC: LDO, 3.5V±2%, 600mA
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • 13 more parts have no package on record. Nothing rules them out, so they stay.
    • BZT52C6V2KZener diode, Taiwan SemiconductorZener diodeNot recordedTaiwan Semiconductor
      What it is
      Zener diode
      Maker
      Taiwan Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • FAN48630UC50XDC-DC converter, onsemiDC-DC converterNot recordedonsemi
      What it is
      DC-DC converter
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Synchronous Regulator with Bypass Mode, , TINYBOOST 2.5 MHz, 1500 mA
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • HFCN-2275+RF filter, Mini-CircuitsRF filterNot recordedMini-Circuits
      What it is
      RF filter
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LTCC filter, 2450-7000 MHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: This part.

    • MM5Z6V2-Q1Zener diode, Formosa MicrosemiZener diodeNot recordedFormosa Microsemi
      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • AP8821N-18GIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.8V±2%, -Reset ODO, H-free
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8821N-18GSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.8V±2%, -Reset ODO, H-free
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8821N-18PIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.8V±2%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8821N-18PSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.8V±2%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • EC95808N18C7IVoltage supervisor, E-CMOSVoltage supervisorNot recordedE-CMOS
      What it is
      Voltage supervisor
      Maker
      E-CMOS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.8V±2%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • EC95808N18C7SVoltage supervisor, E-CMOSVoltage supervisorNot recordedE-CMOS
      What it is
      Voltage supervisor
      Maker
      E-CMOS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.8V±2%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • KRA741EKECNot recordedNot recordedKEC
      What it is
      Not recorded
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      PNP transistor: Dual, Sw, 50V, 100mA, 200mW, R1/R2=47k/10k
      Source
      Published code list

      Is it dead? The meter test is below: Bipolar transistor.

    • KRA741UKECNot recordedNot recordedKEC
      What it is
      Not recorded
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      PNP transistor: Dual, Sw, 50V, 100mA, 200mW, R1/R2=47k/10k
      Source
      Published code list

      Is it dead? The meter test is below: Bipolar transistor.

    • RN1969FSToshibaNot recordedNot recordedToshiba
      What it is
      Not recorded
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn-Digi: Dual, Sw, 20V, 50mA, 50mW, 250MHz, R1/R2=47k/22k
      Source
      Published code list

      Is it dead? The meter test is below: This part.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as J8

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with J8

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 18 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.