SMD code K7p
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, p, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and K7 was searched.
62 parts are printed K7p
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
2SK160K7SOT-233 pinsNot recordedSOT-233 pinsNot recorded
- What it is
- Not recorded
- Maker
- Not recorded
- Package
- SOT-23
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SK853-7SOT-3233 pins, NEC ElectronicsNot recordedSOT-3233 pinsNEC Electronics
- What it is
- Not recorded
- Maker
- NEC Electronics
- Package
- SOT-323
- Pins
- 3
- Details
- FET n-type: GP, 30V, 10mA, 150mW, Idss=6..12mA, Up<4.5V
- Source
- Published code list
Is it dead? The meter test is below: MOSFET.
AP8821N-27GCSOT-23Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-233 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-27GTSOT-323Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-3233 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-27PCSOT-23Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-233 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-27PTSOT-323Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-3233 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BAP1321-02SOD-5232 pins, PhiNot recordedSOD-5232 pinsPhi
- What it is
- Not recorded
- Maker
- Phi
- Package
- SOD-523
- Pins
- 2
- Details
- PIN-diode: RF, 60V, 100mA, 715mW, 0,45pF, 1,3Ω(100mA/100MHz)
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
BC847PNSOT-363Transistor, 6 pins, Diodes IncorporatedTransistorSOT-3636 pinsDiodes Incorporated
- What it is
- Transistor
- Maker
- Diodes Incorporated
- Package
- SOT-363
- Pins
- 6
- Details
- SMD General Purpose NPN+PNP Transistors
- Source
- Published code list
Is it dead? The meter test is below: Bipolar transistor.
BZX84C3V6TSOT-523Zener diode, 3 pins, Silicon-Based TechnologyZener diodeSOT-5233 pinsSilicon-Based Technology
- What it is
- Zener diode
- Maker
- Silicon-Based Technology
- Package
- SOT-523
- Pins
- 3
- Details
- zener 150mW 3.6V
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
6 more parts have no package on record
AP8821N-27GIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-27GSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-27PIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-27PSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BAP1321-012 pins, Philips SemiconductorsNot recordedNot recorded2 pinsPhilips Semiconductors
- What it is
- Not recorded
- Maker
- Philips Semiconductors
- Package
- Not recorded
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: This part.
BD46E475G-MVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.7V±1%, -MR, -Reset PPO, Rdt=50ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Bipolar transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.