SMD code K8 in SOD-882
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
2 parts in SOD-882 are printed K8
Not sure which one you have?
Answer up to 4 quick questions and these 19 parts are ranked, with a meter test that settles it. It works on a dead part too.
MM8Z15VB-CSOD-882Zener diode, SeCoSZener diodeSeCoS
- What it is
- Zener diode
- Maker
- SeCoS
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
PZU5.6B2LSOD-882Zener diode, NXPZener diodeNXP
- What it is
- Zener diode
- Maker
- NXP
- Package
- SOD-882
- Pins
- 2
- Details
- Zener diode: 5.49..5.73V, Zzt=40(Iz=5mA), 250mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
13 more parts have no package on record. Nothing rules them out, so they stay.
BZT52C6V8KZener diode, Taiwan SemiconductorZener diodeTaiwan Semiconductor
- What it is
- Zener diode
- Maker
- Taiwan Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM5Z6V8-Q1Zener diode, Formosa MicrosemiZener diodeFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
AP8821N-28GIVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.8V±2%, -Reset ODO, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-28GSVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.8V±2%, -Reset ODO, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-28PIVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.8V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821N-28PSVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.8V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BD46E485G-MVoltage supervisor, ROHMVoltage supervisorROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.8V±1%, -MR, -Reset PPO, Rdt=50ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
EC95808N28C7IVoltage supervisor, E-CMOSVoltage supervisorE-CMOS
- What it is
- Voltage supervisor
- Maker
- E-CMOS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.8V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
EC95808N28C7SVoltage supervisor, E-CMOSVoltage supervisorE-CMOS
- What it is
- Voltage supervisor
- Maker
- E-CMOS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.8V±2%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
LDTB113ZET1GDigital transistor (PNP, resistors built in), LRCDigital transistor (PNP, resistors built in)LRC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- PNP transistor: Sw., 50V, 500mA, B>56, R1/R2=1k/10k
- Source
- Published code list
Is it dead? The meter test is below: Digital transistor.
R5426D107CANisshinbo Micro DevicesNot recordedNisshinbo Micro Devices
- What it is
- Not recorded
- Maker
- Nisshinbo Micro Devices
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Li-Ion Battery Over-charge/discharge Protection, Vc/d=1,07V
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
RN2969FSToshibaNot recordedToshiba
- What it is
- Not recorded
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Si-pnp-Digi: Dual, Sw, 20V, 50mA, 50mW, R1/R2=47k/22k
- Source
- Published code list
Is it dead? The meter test is below: This part.
XC6GN0802HRTorexNot recordedTorex
- What it is
- Not recorded
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 0,8V, Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as K8
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.