Skip to content

SMD code K84

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

K84 on a chip resistor

840 Ω

840 Ω resistor

The K is both the decimal point and the multiplier: 840 Ω.

Check it with a meter

Lift one end and measure across it. A good one reads 840 Ω. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 840 Ω on the board is a fault. Open, or well above 840 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 840 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (SOT-23-5, SOT-363, USP-6C), K84 is a part code instead. Those parts are listed below.

5 parts are printed K84

Not sure which one you have?

Answer up to 4 quick questions and these 5 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • GSFK0501SOT-363Dual P-channel MOSFET, 6 pins, Good-ArkDual P-channel MOSFETSOT-3636 pinsGood-Ark
    What it is
    Dual P-channel MOSFET
    Maker
    Good-Ark
    Package
    SOT-363
    Pins
    6
    Details
    Dual P-channel MOSFET, 50 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: P-channel MOSFET pair.

  • SUM84DW-CSOT-363MOSFET, 6 pins, SeCoSMOSFETSOT-3636 pinsSeCoS
    What it is
    MOSFET
    Maker
    SeCoS
    Package
    SOT-363
    Pins
    6
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: MOSFET.

  • BSS84SOT-23P-channel MOSFET, 3 pins, Diodes IncorporatedP-channel MOSFETSOT-233 pinsDiodes Incorporated
    What it is
    P-channel MOSFET
    Maker
    Diodes Incorporated
    Package
    SOT-23
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: P-channel MOSFET.

  • BSS84DWSOT-363P-channel MOSFET, 6 pins, Diodes IncorporatedP-channel MOSFETSOT-3636 pinsDiodes Incorporated
    What it is
    P-channel MOSFET
    Maker
    Diodes Incorporated
    Package
    SOT-363
    Pins
    6
    Details
    p-MOS*-e: Dual, V-MOS, LogL, 50V, 130mA, 0,3W, 6Ω(0,1A), 10/18ns
    Source
    Published code list

    Is it dead? The meter test is below: P-channel MOSFET.

  • BSS84WSOT-323P-channel MOSFET, 3 pins, Diodes IncorporatedP-channel MOSFETSOT-3233 pinsDiodes Incorporated
    What it is
    P-channel MOSFET
    Maker
    Diodes Incorporated
    Package
    SOT-323
    Pins
    3
    Details
    Pch -60V -0.21A Small Signal MOSFET
    Source
    Published code list

    Is it dead? The meter test is below: P-channel MOSFET.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

P-channel MOSFET pair

Diode range, part lifted. Test drain to source first, then short gate to source and test again. Test each MOSFET on its own pins, as the datasheet's pinout gives them.

Working, it reads

Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

P-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as K84

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with K84

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.