Skip to content

SMD code KD-

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

94 parts are printed KD-

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BU4920FP3SOT-89Voltage supervisor, 3 pins, ROHMVoltage supervisorSOT-893 pinsROHM
    What it is
    Voltage supervisor
    Maker
    ROHM
    Package
    SOT-89
    Pins
    3
    Details
    Voltage detector IC: 2.0V±1%,+Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BZX84C8V2CCSOT-23Zener diode, 3 pins, JinYu semiconductorZener diodeSOT-233 pinsJinYu semiconductor
    What it is
    Zener diode
    Maker
    JinYu semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode: Dual, 7.7..8.7V, Zzt=15, Izt=5mA, 350mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • DDZ2V4BSFSOD-323Zener diode, 2 pins, Diodes IncorporatedZener diodeSOD-3232 pinsDiodes Incorporated
    What it is
    Zener diode
    Maker
    Diodes Incorporated
    Package
    SOD-323
    Pins
    2
    Details
    Zener diode: 2.43..2.63V, Izt=20mA, Zzt=100, 500mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • DZ23C8V2SOT-23Zener diode, 3 pins, Luguang Electronic TechnologyZener diodeSOT-233 pinsLuguang Electronic Technology
    What it is
    Zener diode
    Maker
    Luguang Electronic Technology
    Package
    SOT-23
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • EC76SMBJ5.0SMBTVS diode, 2 pins, E-CMOSTVS diodeSMB2 pinsE-CMOS
    What it is
    TVS diode
    Maker
    E-CMOS
    Package
    SMB
    Pins
    2
    Details
    Transient voltage supressor: Vbr=6.40..7.82V, Vrwm=5.0V, Ipp=62.5A, 600W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • ELM7314NAC1ASOT-343Voltage supervisor, 4 pins, ELM TechnologyVoltage supervisorSOT-3434 pinsELM Technology
    What it is
    Voltage supervisor
    Maker
    ELM Technology
    Package
    SOT-343
    Pins
    4
    Details
    Voltage detector IC: 1.4V±30mV, -Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • ELM7314NBC1ASOT-353Voltage supervisor, 5 pins, ELM TechnologyVoltage supervisorSOT-3535 pinsELM Technology
    What it is
    Voltage supervisor
    Maker
    ELM Technology
    Package
    SOT-353
    Pins
    5
    Details
    Voltage detector IC: 1.4V±30mV, -Reset ODO, -MR
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • ELM7623HDBSOT-23Voltage supervisor, 3 pins, ELM TechnologyVoltage supervisorSOT-233 pinsELM Technology
    What it is
    Voltage supervisor
    Maker
    ELM Technology
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 2.3V±2%, +Reset PPO, Rdt=50ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • FP6811-29NC4PSOT-343Voltage supervisor, 4 pins, FitipowerVoltage supervisorSOT-3434 pinsFitipower
    What it is
    Voltage supervisor
    Maker
    Fitipower
    Package
    SOT-343
    Pins
    4
    Details
    Voltage detector IC: 2.93V±1.5%, -Reset ODO, -MR
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 6 more parts have no package on record
    • BU46L402GVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.0V±1%, -Reset PPO, Rdt=200ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4920FVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 2V, Reset Push-pull output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4920FWEVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 2V, Reset Push-pull output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BU4920GVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 2V, Reset Push-pull output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • FP6811-29NC8PVoltage supervisor, FitipowerVoltage supervisorNot recordedNot recordedFitipower
      What it is
      Voltage supervisor
      Maker
      Fitipower
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 2.93V±1.5%, -Reset ODO, -MR
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • FP6812-46CC8PVoltage supervisor, FitipowerVoltage supervisorNot recordedNot recordedFitipower
      What it is
      Voltage supervisor
      Maker
      Fitipower
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.63V±1.5%, +Reset PPO, -MR
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.